Installing  the  water  heater:
This  water  heater  must  be  installed  in  accordance  with  these  instructions,  local  codes,  utility  company  
requirements  and/or  in  the  absence  of  local  codes,  use  the  latest  edition  of  the   A merican  National  Standard/
National  Fuel  Gas  Code.   A  copy  can  be  purchased  from  either  the   A merican  Gas   A ssociation,  400  North  
Capitol  Street  Northwest,  Washington,  DC  20001  as   A NSI  standard  Z223.1  or  National  Fire  Protection  
Association,  1  Batterymarch  Park,  Quincy,  MA  02269  as  NFPA  54.  In  Canada,  the  latest  edition  of  the  CSA  
B149.1  Natural  Gas  and  Propane  Installation,  and  the  Canadian  Electrical  Code,  CSA  C22.1  Part  1,  in  the  
absence  of  local  codes.
!
WARNING:  Combustible  
construction  refers  to  
adjacent  walls  and  ceilings  
and  should  not  be  confused  
with  combustible  or  
flammable  products  and  
materials.  Combustible  
and/or  flammable  products  
and  materials  should  never  
be  stored  in  the  vicinity  of  
this  or  any  gas  appliance.
!
CAUTION:
Protect  plastic,  paint  or  
other  items  sensitive  to  heat  
using  non-­combustible  
insulation  if  these  are  
exposed  to  the  flue  exhaust  
even  though  they  may  be  
more  than  24"  (61  cm)  away  
from  the  water  heater.
AP15318 tankless 10 30 09.indd 7
Location  of  the  water  heater
This  water  heater  is  for  OUTDOOR  
installation  ONLY!  
This  water  heater  is  an  outdoor  model  
and  must  be  mounted  vertically.  It    
must  not  be  installed  indoors  or  in  an  
enclosure.
The  water  heater  should  be  installed  
close  to  the  most  frequently  used  outlet  
and  its  position  chosen  with  safety  and  
service  in  mind.
Make  sure  people  (particular  children,  
disabled,  and  elderly)  will  not  touch  the  
hot  water  outlet  or  the  flue  terminal.  
The  flue  terminal  and  air  inlet  must  be  
clear  of  obstruction  and  shrubbery.
The  water  heater  should  not  be  located  
in  an  area  where  leakage  of  the  heat  
exchanger  or  connections  will  result    
in  damage  to  the  area  adjacent  to  it    
or  to  lower  floors  of  the  structure.  
A  gas  fired  water  heater  or  any  other  
appliance  should  not  be  installed  in    
a  space  where  liquids  which  give  off  
flammable  vapors  are  to  be  used  or  stored.    
Such  liquids  include  gasoline,  but  are  not  
limited  to,  LP  gas  (butane  or  propane),  
paint  or  adhesives  and  their  thinners,  
solvents  or  removers.
Because  of  natural  air  movement  in  a  room  
or  other  enclosed  space,  flammable  vapors  
can  be  carried  some  distance  from  where  
their  liquids  are  being  used  or  stored.  The  
open  flame  of  the  water  heater's  main  
burner  can  ignite  these  vapors,  causing  
an  explosion  or  fire  which  may  result  in  
severe  burns,  death  or  property  damage.
Minimum  Clearance  from  Combustible  and    
Non-­Combustible  Construction.
min.
1/2 "
(1.3 cm)
min. 12" (30 cm)
(24" (61 cm) minimum is
recommended for service)
Front = 12" (30 cm)
Side = 1/2" (1.3 cm)
Back = 0" (with support bracket)
Bottom = 12" (30 cm)
The  water  heater  must  be  located  so  it  is  not  
subject  to  physical  damage,  for  example,  by  
moving  vehicles,  area  flooding,  etc.
G     The  water  heater  should  be  installed  
vertically  with  the  water,  gas  and  power  
connections  on  the  underside  pointing  
toward  the  ground.  
  Failure  to  properly  install  the  water  heater  
G
outdoors  as  outlined  in  this  manual  can  
result  in  unsafe  operation.
G     Hot  and  cold  water  lines  should  be  insulated  
to  conserve  water  and  energy.  
G     The  water  heater  and  water  lines  should  
be  protected  from  exposure  to  freezing  
temperatures.
G     Do  not  install  water  heater  where  subject  
to  vibrations.
G     Do  not  install  the  water  heater  in  
Recreational  Vehicles,  Mobile  Homes,  
Boats  and  other  Watercrafts.
G     Do  not  install  the  water  heater  near  
vents  for  heating  or  cooling.   A  minimum  
of  4  feet  should  be  maintained.
G     Minimum  clearance  from  combustible  
and  noncombustible  construction  is    
1/2"  (1.3  cm)  sides,  0"  rear  (with  support  
bracket);;  12"  (30  cm)  from  the  bottom;;  
12"  (30  cm)  from  the  front  of  the  
water  heater;;  (24"  [61  cm]  from  front  
recommended  for  servicing  purposes).    
If  the  clearances  stated  on  the  Instruction/  
Warning  Label,  located  on  the  front  panel  
of  the  heater  differ,  install  the  water  
heater  according  to  the  clearances  stated  
on  the  label.
Top:  Do  not  install  this  water  
min.
heater  under  an  overhang  less  
1/2 "
(1.3 cm)
than  36"  (91  cm)  from  its  top.  
The  area  under  the  overhang  
must  be  open  on  3  sides.