Gas  Supply; High   A Ltitude - Ruud AP15318 Use & Care Manual

Outdoor gas tankless water heater
Table of Contents

Advertisement

WARNING:  Do  not  attempt  to  convert  this  water  heater  for  use  with  a  different  type  of  gas  other  than  the  type  shown  
on  the  rating  plate.  Such  conversion  could  result  in  hazardous  operating  conditions.
Manual
Gas
Supply
Line
Shutoff
(Valve)
Manual Gas
Appliance
Shutoff
(Supplied)
Union
Sediment Trap
Cap
WARNING:  Never  use  
an  open  flame  to  test  for  
gas  leaks,  as  property  
damage,  personal  injury,    
or  death  could  result.
WARNING:  Install  a  gas  
pressure  regulator,  in  the  
gas  supply  line,  which  does  
not  exceed  the  maximum  
supply  pressure.
DO  NOT  use  an  industrial  
type  gas  regulator.
14
AP15318 tankless 10 30 09.indd 14
Gas  Supply
The  supplied  Manual  Gas   A ppliance  Shutoff  
Valve  must  be  installed  at  the  gas  connection  of  
the  water  heater  at  the  time  of  installation  (see  
diagram  to  the  left).
The  branch  gas  supply  line  to  the  water  heater  
should  be  a  minimum  of  3/4"  black  steel  pipe  
or  other  approved  gas  piping  material.
A  ground  joint  union  or   A NSI  design  certified  
semi-­rigid  or  flexible  gas  appliance  connector  
should  be  installed  in  the  gas  line  close  to  the  
water  heater.  The  National  Fuel  Gas  Code  
(NFGC)   A NSI  Z223.1  and  CAN  B149  code  
mandates  a  manual  gas  shut-­off  valve:  See  
NFGC  &  B149  for  complete  instructions.
If  flexible  connectors  are  used,  the  maximum  
length  shall  not  exceed  36"  (91  cm).
If  lever  type  gas  shut  offs  are  used,  they  shall  
be  approved/certified  gas  cocks..
Compound  used  on  the  threaded  joints  of  the  
gas  piping  must  be  of  the  type  resistant  to  the  
action  of  LP  gas.  Use  compound  sparingly  on  
male  threads  only.  
Leak  Testing
The  water  heater  and  its  gas  connections  must  
be  leak  tested  at  normal  operating  pressures  
before  it  is  placed  in  operation.
      Turn  on  the  gas  shut-­off  valve(s)  to  the  
water  heater.
Pressure  Testing  the  Gas  Supply  System
The  water  heater  and  its  manual  gas  shut-­
off  valve  must  be  disconnected  from  the  gas  
supply  piping  system  during  any  pressure  
testing  of  the  system  at  pressures  in  excess    
of  1/2  psi  (14"  w.c.  [3.5  kPa]).
High   A ltitude
This  water  heater  is  certified  for  installations  
up  to  3,280  feet  (1000  m)  above  sea  level.  
The  input  rating  of  this  water  heater  is  based  
on  sea  level  operation.  At  higher    
elevations,  the  actual  input  rate  may  be  
lower  than  the  value  listed  on  the  rating  
label.
A  sediment  trap  should  be  installed  at  the  
bottom  of  the  gas  line.
Do  not  use  excessive  force  (over  31.5  ft  lbs.  
[42.7  Nm])  in  tightening  the  pipe,  particularly  if  
teflon  pipe  compound  is  used,  as  the  unit  may  
be  damaged.
The  inlet  gas  pressure  to  the  water  heater  must  
not  exceed  10.5"  w.c.  (2.6  kPa)  for  natural  or  
13"  w.c.  (3.2  kPa)  for  LP  gas.  For  purposes    
of  input  adjustment,  the  minimum  inlet  gas  
pressure  (with  main  burner  on)  is  shown  on  
the  water  heater  rating  plate.  If  high  or  low  gas  
pressures  are  present,  contact  your  gas  supplier  
for  correction.
NOTICE:  To  ensure  proper  operation  of  the  
heater  the  gas  pipe  and  gas  meter  must  be  sized  
correctly.
Gas  piping  shall  be  in  accordance  with  local,  
utility  company  requirement  and/or  in  the    
absence  of  local  codes,  use  the  latest  edition  of  
the  National  Fuel  Gas  Code.  In  Canada,  the  latest  
edition  of  CSA  B149.1  Natural  Gas  and  Propane  
installation  code.
      Use  a  soapy  water  solution  to  test  for  
leaks  at  all  connections  and  fittings.  
Bubbles  indicate  a  gas  leak  that  must    
be  corrected.  
The  factory  connections  should  also  be  leak  
tested  after  the  water  heater  is  placed  in  
operation.
The  water  heater  must  be  isolated  from  the  
gas  piping  system  by  closing  the  manual  gas  
shut-­off  valve  during  any  pressure  testing  of  
the  gas  supply  piping  at  pressures  equal  to  or  
less  than  1/2  psi  (14"  w.c.  [3.5  kPa]).
NOTICE:  For  installations  above  3,280  
feet  (1,000  m)  elevation,  contact  a  quaili-­
fied  service  technician  to  make  the  proper  
altitude  adjustment.    See  page  31  for  ad-­
ditional  information.
Do  not  install  this  water  heater  at  eleva-­
tions  above  3,280  feet  (1,000  m)  without  
making  the  proper  adjustment.  Please  
contact  your  installer,  local  gas  supplier,  
place  of  purchase  or  the  Customer  Service  
phone  number  as  listed  in  this  Use  &  Care  
Manual  for  more  information.  