Ruud AP15318 Use & Care Manual page 10

Outdoor gas tankless water heater
Table of Contents

Advertisement

Installing  the  water  heater:
Outdoor  Water  Heater
Caulk
If soffit vent is too close,
block off and install new
vent at another location
Inside
corner
6' (1.8 m) caulk
zone
Caulk
4'
(1.2 m)
WARNING
Moisture  in  the  flue  gas  will  condense  as  
:  
it  leaves  the  vent  terminal.  In  cold  weather  this  condensate  
can  freeze  on  the  exterior  wall,  under  the  eaves  and  on  
surrounding  objects.  Some  discoloration  on  the  exterior  of  
the  building  is  to  be  expected.  However,  improper  location  
or  installation  can  result  in  severe  damage  to  the  structure  
or  exterior  finish  of  the  building.
10
AP15318 tankless 10 30 09.indd 10
Rising moisture will collect under eaves
(1.8 m)
6'
6' (1.8 m)
caulk zone or
to edge of
window etc., starting
within 6' (1.8 m)
Caulk
12" (30 cm)
Additional  Considerations
Do  NOT  install  vent  terminal  under  any  patio  or  deck.
   
    To  help  prevent  moisture  from  freezing  on  walls  and  under  
eaves,  do  not  locate  vent  terminal  on  the  side  of  a  build   ing  with  
prevailing  winter  winds.
  T o  help  prevent  water  lines  from  freezing,  do  not  locate  vent  
terminal  on  the  side  of  a  building  with  prevailing  winter  winds.
        Do  NOT  locate  vent  terminal  too  close  to  shrubbery,  as  flue  gases  
may  damage  them.
      All  painted  surfaces  should  be  primed  to  lessen  the  chance  of  
physical  damage.  Painted  surfaces  will  require  maintenance.
Guard  vent  against  accidental  contact  with  people  and  pets.
 
 
Install  outdoor  water  heater  such  that  air  inlet  and  flue  outlet  is  
above  anticipated  snow  level.