Error  Code  Guide:
When  an  error  code  is  displayed:
G     Close  the  hot  water  faucet,  turn  off  the  switch  on  the  remote  
control.
G     Wait  for  about  5  minutes  before  turning  the  switch  on  
again.
G     Open  the  hot  water  faucet.
If  the  error  code  remains  in  the  display:
G     Close  the  hot  water  faucet  and  turn  off  the  switch  on  the  
remote  control.
G     Take  the  proper  action  shown  below  and  attempt  operation  
of  the  appliance  again.
Error  Code
11  or  12
15
1L
99
CAUTION:  Make  certain  power  to  water  heater  is  "OFF"  before  removing  protective  cover  FOR   A NY  REASON.
CAUTION:  Label  all  wires  prior  to  disconnection  when  servicing  controls.  Wiring  errors  can  cause  improper  and  
dangerous  operation.    VERIFY  PROPER  OPERATION   A FTER  SERVICING.
CAUTION:  For  your  safety,  DO  NOT  attempt  repair  of  gas  piping,  remote  control,  burners,  vent  connectors  or  other  
safety  devices.  Refer  repairs  to  qualified  service  personnel.
28
AP15318 tankless 10 30 09.indd 28
Possible  Cause
The  Gas  shutoff  valve  is  not  opened  fully.
Gas  service  has  been  interrupted.
LP  Gas  is  running  low.  (LP  models  only).
Air  in  Gas  Line.
Power  supply  not  grounded.
Low  inlet  gas  pressure  due  to  improper  sizing
Wrong  gas  type.
The  hot  water  faucet  is  not  opened  enough.
Water  heater  has  build  up  of  lime  deposits.
Water  heater  has  buildup  of  lime  deposits.
Decrease  of  blower  motor  ventilation  volume.  
(Operation  Stops)
If  the  error  code  is  still  shown:
G     Turn  off  the  hot  water  faucet  and  turn  off  the  switch  on  the  
remote  control.
G     Take  note  of  the  error  code  displayed  and  call  the  customer  
service  assistance  number  in  the  "If  You  Need  Service"  
section  of  the  manual  on  the  back  cover.
Notice:  If  an  error  code  other  than  those  listed  below  is  
displayed,  immediately  turn  off  the  hot  water  faucet,  take  note  
of  the  error  code,  turn  off  the  switch  on  the  remote  control  and  
call  the  customer  assistance  number.
What  To  Do
Open  the  Gas  shutoff  valve  fully.
G
Contact  gas  utility  company.
G
Fill  up  LP  Gas  container  or  replace  with  
G
a  new  cylinder  of  LP  Gas.
Bleed  all  air  from  gas  lines.
G
Ensure  appliance  is  properly  grounded.
G
Ensure  gas  line,  meter,  and  regulator  are  
G
sized  properly.
Ensure  gas  type  is  correct.
G
Ensure  venting  is  per  Use  &  Care  
G
Manual.  Contact  a  dealer  for  service.
Open  the  faucet  more  to  secure  enough  
G
volume.
G  
Contact  a  dealer  for  service.
Contact  a  dealer  for  service.
G
Clean  any  blockage  from  heat  exchanger  
G
fins  and/or  blower  motor