Electrical  Connection - Ruud AP15318 Use & Care Manual

Outdoor gas tankless water heater
Table of Contents

Advertisement

Installing  the  Main  Remote  Control:
WARNING:  Field  wiring  connections  and  electrical  grounding  must  comply  with  local  codes,  or  
in  the  absence  of  local  codes,  with  the  latest  edition  of  the  National  Electrical  Code,   A NSI/NFPA  70,  
or  in  Canada,  Canadian  Electrical  Code,  CSA  C22.1  Part  1.
  WARNING:  Shock  
hazard  line  voltage  is  
present.  Before  servicing  
the  water  heater,  turn  off  
the  electrical  power  to  the  
water  heater  at  the  main  
disconnect  or  circuit  
breaker.  Failure  to  do  so  
could  result  in  severe  
personal  injury  or  death.
CAUTION:  Label  
all  wires  prior  to  
disconnection  when  
servicing  controls.  Wiring  
errors  can  cause  improper  
and  dangerous  operation.  
Verify  correct  operation  
after  servicing.
WIRING DIAGRAM
SCHÉMA DE CÂBLAGE
FOR DIRECT-VENT MODEL ONLY
POUR MODÈLE À ÉVENT DIRECT SEULEMENT
SOLENOID VALVE 4
ÉLECTROVALVE 4
SOLENOID VALVE 3
ÉLECTROVALVE 3
SOLENOID VALVE 2
ÉLECTROVALVE 2
SOLENOID VALVE 1
ÉLECTROVALVE 1
GAS INLET
SOLENOID VALVE 0
ÉLECTROVALVE DANS
ADMISSION DE GAZ
ELECTRODE
ÉLECTRODE
ANTI-FROST HEATER
CHAUFFAGE ANTI-GIVRE
BK
AC
G/YorG
120V
W
FOR INDOOR,DIRECT-VENT
MODEL ONLY
POUR MODÈLE INTÉRIEUR À
ÉVENT DIRECT SEULEMENT
AP15318 tankless 10 30 09.indd 17
Electrical  Connection
POWER  CORD
   
G     The  electric  power  supply  requirement  
for  this  water  heater  is  120  VAC/60HZ,    
2   A mps.
G     A  power  supply  cord  is  not    supplied  with  
the  water  heater.  Use  only  a  power  outlet  
with  a  ground  terminal.
G     The  installation  of  an  GFCI  (Ground  Fault  
Circuit  Interrupter)  is  recommended.
G     Keep  any  excess  of  the  power  supply  cord  
on  the  outside  of  the  water  heater.
G     If  local  codes  require  hardwiring,  see  
instructions  for  "Hardwiring  the  Electrical  
Connections".
FAN MOTOR
5
FM
MOTEUR DU
VENTILATEUR
R BK
W
Y
BL
W BL R O Y
SW1
G
6
5
4
3
2
1
SV4
MIN BUTTON
BOUTON MIN.
BK
GND
SV3
CIRCUIT BOARD
PLAQUE DE CIRCUIT
SV2
BK
LED
G/Y
SV1
BK
BK
BK
R
SV0
8
7
6
5
W
BK
K
BL
4
3
2
1
W
7
RESISTOR
GY
W
Y
6
RÉSISTANCE
5
4
3
BK
IG
2
1
IGNITER
GY
GY
ALLUMEUR
R
4
3
H
2
1
W
W
W
W
BK
BK
W
W
FUSE(3A)
J
I
GND
FUSIBLE(3A)
OVER HEAT LIMITER
W
LIMITEUR DE SURCHAUFFE
W
HARDWIRING  
THE  ELECTRICAL  CONNECTIONS    
G     Wiring  should  be  carried  out  by  a  qualified  
electrician  in  accordance  with  local  codes.
G     The  water  heater  requires  120  VAC/60Hz  and  
should  be  properly  grounded.
G     DO  NOT  connect  grounding  wire  to  water  
pipes,  gas  pipes,  telephone  cables,  lightning  
conductor  circuits  and  to  grounding  circuit  
of  other  equipment  that  carry  a  ground-­fault  
interrupter.
G     An  ON/OFF  switch  must  be  provided  and  
installed  for  the  incoming  120VAC  power.
G     Wire  the  water  heater  exactly  as  shown  
below.   A  wiring  diagram  is  also  found  
inside  of  the  cover  panel.
G     A  green  screw  is  provided  in  the  junction  
box  for  a  grounding  connection.
G     Connect  the  live  wire  to  black  leg  wire  and  
the  neutral  wire  to  the  white  neutral  wire.
ON
MARCHE
DIP SWITCH 1
CONTACTEUR DIP 1
OFF
1 2 3 4
ARRÉT
ON
MARCHE
FOR INDOOR,DIRECT-VENT
DIP SWITCH 2
MODEL ONLY
CONTACTEUR DIP 2
OFF
POUR MODÈLE INTÉRIEUR À
1
2 3 4
ARRÉT
ÉVENT DIRECT SEULEMENT
SW2
SW3
FLAME ROD 1
MAX BUTTON ADJUSTER BUTTON
ÉLECTRODE DE
BOUTON MAX.
BOUTON DE RÉGLAGE
DÉTECTION
DE FLAMME 1
W
T
FLAME ROD 3
M
BL
ÉLECTRODE DE
DÉTECTION
4 3 2 1
A
DE FLAMME 3
F
5
GAS TYPE
USUALLY
4
CIRCUIT BOARD
DISCONNECTED
3
PLAQUE DE CIRCUIT
NORMALEMENT
2
IMPRIMÉ DE TYPE Â GAZ
DECONNECTE
1
BL
W
Y
R
BK
BK
WATER BY-PASS CONTROL MOTOR
C
R
ÉLECTROVALVE DE DÉRIVATION D'EAU
B
9
LIMITER
MOTOR
BK
BK
8
8
LIMITEUR
MOTEUR
U
R
R
7
7
G
G
6
6
2
5
Y
5
Y
1
BK R
G BL
Y
O W BR
BL
BL
4
4
O
O
3
3
3
W
W
2
2
2
BR
BR
1
1
1
8
S
BL
3
V
2
BL
1
MAIN REMOTE
CONTROL
TÉLÉCOMMANDE
BR
<<MAIN>>
WATER FLOW SENSOR
BK
(UMC-117)
CAPTEUR DE DÉBIT
R
D'EAU
COLOR CODE
CODE DE COULEUR
R:RED,ROUGE
W:WHITE,BLANC
BR:BROWN,BRUN
BK:BLACK,NOIR
BL:BLUE,BLEU
GY:GRAY,GRIS
G:GREEN,VERT
O:ORANGE,ORANGE
Y:YELLOW,JAUNE
G/Y:GREEN/YELLOW,
VERT/JAUNE
R4
AMBIENT AIR
THERMISTOR
THERMISTOR
D' A IR AMBIANT
BK
R3
WATER INLET
THERMISTOR
THERMISTOR
D' A DMISSION D'EAU
BK
R2
HEAT EXCHANGER
THERMISTOR
THERMISTOR
D'ECHANGEUR DE CHALEUR
BK
R1
HOT WATER OUTLET
THERMISTOR
THERMISTOR
DE SORTIE D'EAU CHAUDE
-
P.G.F.R VALVE
PSV
WATER VOLUME CONTROL MOTOR
MOTEUR DE CONTRÔLE DU VOLUME D'EAU
LIMITER
MOTOR
LIMITEUR
MOTEUR
BK R
G
Y
BL
O W BR
8
BATH REMOTE
BATH REMOTE
CONTROL 1
CONTROL 2
TÉLÉCOMMANDE 1
TÉLÉCOMMANDE 2
<<BATH>>
<<BATH>>
(USC1-117)
(USC2-117)
31-93618 0
17
11/9/2009 3:17:39 PM