Leak Testing; Installer Final Check List - Nexgrill 720-0311 Assembly & Operating Instructions

Table of Contents

Advertisement

To disconnect L.P. gas cylinder:
1. Turn the burner valves off.
2. Turn the tank valve off fully (turn clockwise
to stop).
3. Detach the regulator assembly from the
tank valve by turning the quick coupling nut
counterclockwise.
LEAK TEST
GAS FLOW CHECK
Each grill burner is tested and adjusted at the
factory prior to shipment; however, variations in
the local gas supply may make it necessary to
adjust the burners. The flames of the burners
should be visually checked.
Flames should be blue and stable with no
yellow tips, excessive noise or lifting. If any of
these conditions exist, check to see if the air
shutter or burner ports are blocked by dirt,
debris, spider webs, etc. If you have any
questions regarding flame stability, please call
customer service 1-866-984-7455

INSTALLER FINAL CHECK LIST

Specified clearance maintained 24" from
combustibles.
All internal packaging removed.
Knobs turn freely.
Burners are tight and sitting properly on
orifices.
Pressure regulator connected and set for
11.2" W.C. L.P. gas. Gas connections to grill
using hose & regulator assembly provided
(pre-set for 11.0" water column).
Unit tested and free of leaks.
User informed of gas supply shut off valve
location
USER, PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
ALWAYS
CHECK
EVERY L.P. TANK CHANGE
Check all gas supply fittings for leaks before
each use. It is handy to keep a spray bottle of
soapy water near the shut-off valve of the gas
supply line. Spray all the fittings. Bubbles
indicate leaks.
Disconnected
L.P.
threaded valve plugs tightly installed, and
must not be stored in a building, garage or any
other enclosed area.
The gas must be turned off at the supply
cylinder when the unit is not in use.
If the appliance is stored indoors the cylinder
must be disconnected and removed from the
appliance. Cylinders must be stored outdoors
in a well-ventilated area out of the reach of
children.
PROPANE CYLINDER CAUTIONS
a) Do Not store a spare LP-gas cylinder
under or near this appliance.
b) NEVER fill the cylinder beyond 80 percent
full.
c) If the information in "a" and "b" is not
followed exactly, a fire causing death or
serious injury may occur.
13
FOR
LEAKS
AFTER
cylinders
must
have

Advertisement

Table of Contents
loading