ASSEMBLY

Assembly requires two people. Place the treadmill in a cleared area and remove all packing materials. Do not
dispose of the packing materials until the treadmill is assembled. No tools are required.
Note: The underside of the treadmill walking belt is coated with high-performance lubricant. During shipping, a
small amount of lubricant may be transferred to the top of the walking belt, the sides of the walking platform, or
the shipping carton. This does not affect treadmill performance. If there is lubricant on top of the walking belt or
on the sides of the walking platform, wipe off the lubricant with a soft cloth and a mild, non-abrasive cleaner.
If you have additional questions, please call our our Customer Service Department at 08457-089009.
1. With the help of a second person, carefully raise the
Uprights (103) until the Base Wheels (99) are resting on
the floor as shown.
2. Next, make sure that the Lock Knob Sleeve (68) is fully
inserted into the left Upright (103).
Remove the Lock Knob (67) from the Lock Pin (72). Make
sure that the Lock Pin Collar (70) and the Lock Spring
(69) are on the Lock Pin. (Note: If there are two Lock Pin
Collars, place one on each side of the Spring.) Insert the
Lock Pin into the left Upright (103) and tighten the Lock
Knob onto it.
3. Make sure that all parts are tightened before you use the treadmill. Place a mat beneath the treadmill
to protect the floor or carpet. For your benefit, we recommend that you familiarise yourself with the
TROUBLE-SHOOTING AND MAINTENANCE section on pages 23 and 24.
6
1
103
99
2
103
69
70
72
68
67
TROUBLE-SHOOTING AND MAINTENANCE
Most treadmill problems can be solved by following the instructions below. If further assistance is
needed, please call our Customer Service Department at 08457-089009.
PROBLEM
SOLUTION
1. The power does not
a. Make sure that the power cord is plugged into a properly earthed outlet. (See
turn on
HOW TO PLUG IN THE POWER CORD on page 8.) If an extension cord is
needed, use only a 3-conductor, 1mm
m (5 ft.). Important: The treadmill is not compatible with GFCI-equipped outlets.
`
b. Make sure that the key is fully inserted into the console.
c. Check the circuit breaker located on the frame near
the power cord. If the switch protrudes as shown, the
circuit breaker has tripped. To reset the circuit
breaker, wait for five minutes and then press the
switch back in.
d. Check the on/off switch located on the frame near
the power cord. The switch must be in the on posi-
tion.
2. The power turns off
a. Check the circuit breaker and reset it if necessary (see 1. c. above).
during use
b. Make sure that the power cord is plugged in.
c. Remove the key from the console and then reinsert it.
d. Make sure that the on/off switch is in the on position (see 1. d. above).
3. The walking belt
a. If an extension cord is needed, use only a 3-conductor, 1mm
slows when walked
is no longer than 1,5 m (5 ft.).
on
b. If the walking belt is overtightened,
treadmill performance may decrease and
the walking belt may be permanently
damaged. Remove the key and UN-
PLUG THE POWER CORD. Using the
included allen wrench, turn both rear
roller adjustment bolts counterclockwise
1/4 of a turn. When the walking belt is
properly tightened, you should be able to
lift the edges of the walking belt 7 to 10
cm (3 to 4 in.) off the walking platform.
Be careful to keep the walking belt cen-
tred. Plug in the power cord, insert the key and run the treadmill for a few minutes.
Repeat until the walking belt is properly tightened.
2
(14-gauge) cord that is no longer than 1.5
Tripped
Reset
T i
d
Reset
On
Position
2
(14-gauge) cord that
b
7–10 cm
Rear Roller Adjustment Bolts