Optical Parts Disassembly
5-2 Optical parts directions in the Optical Unit
When mounting or assembling the optical parts in the optical unit, the parts must be mounted in the specified location
and direction as shown in the figure below.
Polarized glass (IN/GB)
Mount as the marker facing to the prism side as shown
in the figure below.
Dichroic mirror
Mount them as shown in the figure below. Pay attention to the direction of the
printed parts no. on the mirror.
LX700 Service Manual
Printed marker
Printed marker
Mirror, Dichroic mirror
Place the mirror and dichroic mirror into the groove
and then mount the stoppers to fix them.
Rev. 1 (11/08)
-39-
Stopper
Printed marker
020-000120-01