Hide thumbs Also See for LW650:

Advertisement

Quick Links

LX750/LW650/LS+700/LW720
U S E R M A N U A L - N E T W O R K G U I D E
020-000160-02

Advertisement

Table of Contents
loading

Summary of Contents for Christie LW650

  • Page 1 LX750/LW650/LS+700/LW720 U S E R M A N U A L - N E T W O R K G U I D E 020-000160-02...
  • Page 2 • Trademark PJLink is a trademark applied for trademark rights in Japan, the United States of America and other countries and areas. All other trademarks are the properties of their respective owners. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 3: Table Of Contents

    3.6 Command Control via the Network ............41 3.7 Controlling the external devise via the projector (using the NETWORK BRIDGE function) ..........46 3.8 Batch-controlling multiple projectors (using the DAISY CHAIN function) ..50 LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 4: Main Functions

    Image files can be sent via the network, and up to 4 image data can be stored in the projector and displayed on screen one by one. (39) Transfer image data Display image data ( LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 5: Equipment Connection And Network Setting

    2) installed a web browser software (11) LAN cable : CAT-5 or greater NOTE • The system for using the network function of the projector requires communication environment conforming 100Base-TX or 10Base-T. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 6: Manual Network Connection Setting

    3) Open “Network and Internet Connections” in “Control Panel”. (Fig. 2.2.2.a) * Administrator authority is the account, which can access to all functions. Fig. 2.2.2.a “Network and Internet Connections” window 4) Open “Network Connections”. (Fig.2.2.2.b) Fig. 2.2.2.b “Network Connections” window LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 7 6) Set used protocol as “TCP/IP” and open “Internet Protocol (TCP/IP) Properties” window. Fig. 2.2.2.d “Internet Protocol (TCP/IP) Properties” window 7) Set IP address, subnet mask and default gateway for PC. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 8 * DHCP is abbreviation for “Dynamic Host Configuration Protocol” and has the function to provide necessary setting for network like IP address from server to client. A server that has DHCP function is called DHCP server. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 9: Internet Option" Setting

    Fig. 2.2.3.a “Network and Internet Connections” window Click Fig. 2.2.3.b “Internet Properties” window 2) Click “Connections” tab and then click [LAN Settings] button to open “Local Area Network (LAN) settings”. (Fig. 2.2.3.c) LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 10: Check Connection

    1) Start browser in PC and specify following URL, then click “ ” button. URL: http://(Projector IP address)/ For example, if projector IP address is 192.168.1.10, specify URL: http://192.168.1.10/ 2) If Fig. 2.2.4 appears, it succeeds. Fig. 2.2.4 “Logon Menu” LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 11: Management With Web Browser Software

    (46) 3.8 Batch-controlling multiple projectors (using the DAISY CHAIN function) Using the DAISY CHAIN function can simultaneously control multiple projectors connected to a shared RS-232C bus, from the computer. (50) LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 12: Configuring And Controlling The Projector Via A Web Browser

    Q832894 (MS04-004) or the web browser interface may not be displayed correctly. And when using an earlier version of Internet Explorer , during ® operations the browser will log out after 50 seconds. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 13 Security Settings √ and other security settings. Projector Control Controls the projector. √ √ Projector Status Displays the current projector status. √ √ Restarts the projector’s network Network Restart √ connection. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 14: Logon

    Fig. 3.1.1 b “Logon with Administrator ID” Fig. 3.1.1 c “Logon with User ID” 3) Click the desired operation or configuration item on the main menu located on the left-hand side of the screen. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 15: Network Information

    Firmware Date is only displayed when logged on using an Administrator ID. Displays the network firmware version number. This Firmware Version information is only displayed when logged on using an Administrator ID. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 16: Network Settings

    You can restart the network connection by clicking [Network Restart] on the main menu. • If you connect the projector to an existing network, consult a network administrator before setting server addresses. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 17: Port Settings

    Configures the image transfer port (Port:9716). (Port:9716) Port open Click the [Enable] check box to use port 9716. Click the [Enable] check box when authentication is required Authentication for this port. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 18 • The new configuration settings are activated after restarting the network connection. When the configuration settings are changed, you must restart the network connection. You can restart the network connection by clicking [Network Restart] on the main menu. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 19: Mail Settings

    Test Mail] button. Please enable Send mail setting before clicking [Send Test Mail]. • If you connect the projector to an existing network, consult a network administrator before setting server addresses. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 20: Alert Settings

    The SNMP access is detected from the invalid SNMP Authentication Failure community. Refer to  “Troubleshooting” in the User’s Manual (detailed) – Operating Guide for further detailed explanation of Error except Other Error and Schedule Execution Error. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 21 Web page, the e-mail will be sent out. • Filter Time Alarm is defined as a threshold for e-mail notification (reminder) of the filter timer. When the filter hour exceeds this threshold, the e-mail will be sent out. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 22: Schedule Settings

    Configures the specific date (No.2) schedule. Specific date No.3 Configures the specific date (No.3) schedule. Specific date No.4 Configures the specific date (No.4) schedule. Specific date No.5 Configures the specific date (No.5) schedule. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 23 • After the projector is moved, check the date and time set for the projector before configuring the schedules. Strong shock may make the date and time settings (23) get out of tune. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 24: Date/Time Settings

    Configures the day of the week daylight savings time ends (Sun, Mon, Tue, Wed, Thu, Fri, Sat). hour Configures the hour daylight savings time ends (0 ~ 23). Time minute Configures the minute daylight savings time ends (0 ~ 59). LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 25 • The projector will retrieve Date and Time information from the time server and override time settings when SNTP is enabled. • The internal clock’s time may not remain accurate. Using SNTP is recommended to maintain accurate time. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 26: Security Settings

    The length of the text can be up to 32 alphanumeric characters. Configures the User password. User Password The length of the text can be up to 255 alphanumeric characters. Re-enter User Reenter the above password for verification. Password LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 27 When the configuration settings are changed, you must restart the network connection. You can restart the network connection by clicking [Network Restart] on the main menu. • Only numbers ‘0-9’ and alphabet ‘a-z’, ‘A-Z’ can be used. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 28: Projector Control

    Selects the P by P Main Area Source setting. MY Image Select MY IMAGE data. MY Image Delete Delete MY IMAGE data. Picture Brightness Adjusts the brightness setting. Contrast Adjusts the contrast setting. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 29 Turns the FRAME LOCK-COMPUTER IN2 function on/off. Computer in 2 Frame Lock-BNC Turns the FRAME LOCK-BNC function on/off. Frame Lock-HDMI Turns the FRAME LOCK-HDMI function on/off. Frame Lock-DVI-D Turns the FRAME LOCK-DVI-D function on/off. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 30 Turns the message function on/off. Template Selects the template setting. C.C. - Display Selects Closed Caption DISPLAY setting. C.C. - Mode Selects Closed Caption MODE setting. C.C. - Channel Selects Closed Caption CHANNEL setting. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 31 Turns the remote control signal frequency nomal function Remote Freq. Normal on/off. Turns the remote control signal frequency high function on/ Remote Freq. High off. Remote ID Selects Remote ID setting. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 32: Projector Status

    Displays the current power status. Input Status Displays the current input signal source. Blank On/Off Displays the current Blank on/off status. Freeze Displays the current Freeze status. Shutter Displays the current Shutter status. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 33: Network Restart

    • The Logon menu (13) is displayed after restarting the projector’s network connection if the DHCP is set to ON. 3.1.13 Logoff When [Logoff] is clicked, the Logon menu is displayed. (13) LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 34: E-Mail Alerts

    The following mail will be delivered to the specified addresses. Subject line :Test Mail <Projector name> Text :Send Test Mail Date <Testing date> Time <Testing time> IP Address <Projector IP address> MAC Address <Projector MAC address> LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 35 Failure/Warning e-mails are formatted as follows: Subject line : <Mail title> <Projector name> Text : <Mail text> Date <Failure/Warning date> Time <Failure/Warning time> IP Address <Projector IP address> MAC Address <Projector MAC address> LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 36: Projector Management Using Snmp

    8) Click [Enable] check box to send out the SNMP trap for Failures/Warnings. Clear [Enable] check box when SNMP trap transmission is not required. 9) Click [Apply] button to save the settings. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 37: Event Scheduling

    (e.g., ‘Specific date No. 1’ has priority over ‘Specific date No. 2’ and so on. • Be sure to set the date and time before enabling scheduled events. (23) LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 38 [ ] or the breaker in a room is tripped. The power indicator will lights orange or green when the projector gets is receiving the power. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 39 Replace the battery by following “Internal clock battery” section of the User's Manual (concise). • The internal clock’s time may not remain accurate. Using SNTP is recommended to maintain accurate time. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 40: My Image (Still Image Transfer) Display

    • It is possible to allocate the image file up to 4 in the maximum. • The image file also can be displayed by using schedule function from the web browser. Refer to the item 3.4 Event Scheduling (36) in detail. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 41 • The new configuration settings are activated after restarting the network connection. When the configuration settings are changed, you must restart the network connection. You can restart the network connection by clicking [Network Restart] on the main menu. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 42: Command Control Via The Network

    5) Click [Enable] check box to open Network Control Port2 (Port: 9715) to use TCP #9715. Click [Enable] check box for [Authentication] setting when authentication is required, otherwise clear the check box. 6) Click [Apply] button to save the settings. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 43 • The new configuration settings are activated after restarting the network connection. When the configuration settings are changed, you must restart the network connection. You can restart the network connection by clicking [Network Restart] on the main menu. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 44: Command Format

    → This is the value to make zero on the addition of the lower 8 bits from the header to the checksum. Connection ID → Random value from 0 to 255 (This value is attached to the reply data) LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 45 Data 0x1D 2 bytes 1 byte <Projector busy reply> Connection Reply Status code 0x1F 2 bytes 1 byte <Authentication error reply> Authentication Connection Reply Error code 0x1F 0x04 0x00 1 byte LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 46 Otherwise, an authentication error will be returned. NOTE • As for the transmission of the second or subsequent commands, the authentication data can be omitted when the same connection. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 47: Controlling The External Devise Via The Projector (Using The Network Bridge Function)

    • Before connecting the devices, read the manuals for the devices to ensure the connection. For RS-232C connection, check the specifications of each port and use the suitable cable. (Operating Guide - Technical - Connection to the ports) LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 48: Communication Setup

    Settings” of web browser. (3.1.4 Port settings – Network Bridge Port) NOTE • Any number between 1024 and 65535 can be set up as the Network Bridge port number. It is set to 9717 as the default setting. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 49 Using the BYTES INTERVAL TIMEOUT menu, set the waiting time for response data to match your system. (Operating Guide - OPTION menu - SERVICE – COMMUNICATION – BYTES INTERVAL TIMEOUT) 50ms  100ms  150ms  200ms ( 50ms) LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 50 • In case that the computer controls to synchronize transmitting and receiving the data, it may not be able to control an external devise well depending on the processing status of the projector. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 51: Batch-Controlling Multiple Projectors (Using The Daisy Chain Function)

    • Turn off (the power switch of) both the projector and other devices and unplug, before connecting them. • Do not apply the DAISY CHAIN function to the system that uses a RS-232C bus distributor. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 52 • An unsuitable setup may cause the malfunction of communication with an external devise. 3.8.3 Communication port When connecting the projector to the computer by Ethernet, send the data from the computer to the projector with using the TCP # 9718 port. LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 53 3.8.5 Command for Daisy Chain control For the command control of the DAISY CHAIN function, see the Technical part of the Operating Guide. (Operating Guide - Technical – Daisy Chain Communication) LIT MAN USR LW650/LS+700/LX750/LW720 NTWK GUID 020-000160-02 Rev.1 (06-2013)
  • Page 54 Corporate offi ces USA – Cypress ph: 714-236-8610 Canada – Kitchener ph: 519-744-8005 Worldwide offi ces United Kingdom Eastern Europe Singapore Japan ph: +44 118 977 8000 ph: +36 (0) 1 47 48 100 ph: +65 6877-8737 ph: 81-3-3599-7481 France Middle East Beijing South Korea...

This manual is also suitable for:

Ls+700Lx750Lw720

Table of Contents