National Instruments NI PXIe-1062Q User Manual page 7

Power supply shuttle
Hide thumbs Also See for NI PXIe-1062Q:
Table of Contents

Advertisement

Slot
System Controller Slot
System Timing Slot
Hybrid Peripheral Slot with
PXI-1 Peripheral
Hybrid Peripheral Slot with
PXI-5 Peripheral
PXI-1 Peripheral Slot
© National Instruments Corporation
Backplane pin current capacity
+5 V
9 A
0 A
6 A
0 A
6 A
Load regulation
Voltage
+3.3 V
+12 V
+5 V
–12 V
Maximum ripple and noise (20 MHz bandwidth)
Voltage
+3.3 V
+12 V
+5 V
–12 V
Over-current protection.......................... All outputs protected from short
Over-voltage protection
3.3 V and 5 V .................................. Clamped at 20 to 30% above
+12 V and –12 V............................. Clamped at 26 to 29 V difference
Power supply shuttle MTTR .................. Replacement in under 5 minutes
V (I/O)
+3.3 V
0 A
9 A
0 A
3 A
5 A
6 A
0 A
3 A
11 A
6 A
Maximum Ripple and Noise
circuit and overload with
automatic recovery
nominal output voltage
between +12 and –12 V outputs
7
NI PXIe-1062Q Power Supply Shuttle User Guide
+12 V
–12 V
5 V
11 A
0 A
2 A
0 A
1 A
1 A
2 A
0 A
1 A
1 A
Load Regulation
<5%
<5%
<5%
<5%
50 mV
pp
120 mV
pp
50 mV
pp
120 mV
pp
AUX
1 A
1 A
0 A
1 A
0 A

Advertisement

Table of Contents
loading

Table of Contents