System Layout And Piping Length - LG AMNH076LQL0 Service Manual

Multi type
Hide thumbs Also See for AMNH076LQL0:
Table of Contents

Advertisement

Installation
5. Branch Distributor
PRECAUTIONS FOR SELECTING THE LOCATION
The BD unit is for indoor use. Install in a location such as above a ceiling or behind a wall in accordance with the
following conditions:
• That the unit is fully supported, and is in a location with little or no vibration.
• That the refrigerant pipes for the indoor and outdoor units can be repaired with ease, and that the units are
placed well within the distance from each other allowed by the pipe length.
• That there is nothing nearby that produces heat or steam(gas).
• When installing, that there is enough carity for servicing the unit.
• Do not install in location that is hot or humid for long periods of time.
• A well-ventilated area.
• Do not install near bedrooms. The sound of refrigerant flowing through the piping may sometimes be audible.
For restrictions on installation, refer to "INSTALLATION".

System Layout and Piping Length

For installation of the indoor units. Follow the instructions in the installation manual for each unit.
System Layout
Distributor Unit
For 2 rooms : PMBD3620 (Ø9.52, Ø6.35)
For 3 rooms : PMBD3630 (Ø9.52, Ø6.35)
For 4 rooms : PMBD3640 (Ø9.52, Ø6.35)
For 3 rooms : PMBD7230 (A: Ø12.7, Ø6.35)
Do not connect more than 8 indoor
units together choose the distributor
unit type (2rooms,3rooms or 4rooms)
according to the installation pattern
82 Multi type Air Conditioner
(B: Ø15.88, Ø6.35)
(C: Ø15.88, Ø6.35)
40K(6rooms)
Branch
Distributor
A
Branch
Distributor
h1
B
48K~56K(7~8rooms)
Branch
Pipe
L1
L2
L3
L5
L6
L7
L8
• Y Branch Pipe
- Included in outdoor unit
- Can not be purchased separately
Main Pipe
L4
h2