- VE chassis
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for piping
connections must be done safely.
CHASSIS
(Grade)
A
B
VE
180
115
Mounting the anchor Nut & Bolt

(Ceiling Mounting)

• Prepare 4 suspension bolts (Each bolts length
should be same.)
• Measure and mark the position for the Suspension
bolts and the piping hole.
• Insert the nuts and washer onto the suspension
bolts for locking the suspension bolts on the ceil-
ing.
• Mount the suspension bolts to the anchor-nuts
firmly.
Distance (mm)
C
D
E
-
115
50
Installation Plate
Type "A" screw
C
Installation plate
Ø70mm
Left rear piping
Installation plate
Installation plate
C
E
Left rear piping
Service Manual 51
Installation
A
Ø70mm
Right rear piping
A
Right rear piping
Ø70mm