LG AMNH076LQL0 Service Manual page 46

Multi type
Hide thumbs Also See for AMNH076LQL0:
Table of Contents

Advertisement

Installation
7. Wrap the insulation material around the con-
necting portion.
• Overlap the connection pipe heat insulation and the
indoor unit pipe heat insulation material. Bind them
together with vinyl tape so that there is no gap.
Plastic bands Insulation material
• Wrap the area which accommodates the rear piping
housing section with vinyl tape.
Connection
pipe
Vinyl tape
(wide)
Connecting cable
• Bundle the piping and drain hose together by wrap-
ping them with cloth tape over the range within which
they fit into the rear piping housing section.
Drain hose
8. Reroute the pipings and the drain hose across the
back of the chassis.
Piping for
passage through
piping hole
46 Multi type Air Conditioner
Indoor
unit piping
Wrap with vinyl tape
Pipe
Vinyl tape(narrow)
Pipe
Vinyl tape(narrow)
Wrap with
vinyl tape(wide)
9. Set the pipings and the drain hose to the back of
the chassis with the tubing holder.
• Hook the edge of tubing holder to tap on chassis and
push the bottom of tubing holder to be engaged at the
bottom of chassis.
10. Indoor unit installation
• Remove the spacer.
• Ensure that the hooks are properly seated on the
installation plate by moving it left and right.
Press the lower left and right sides of the unit against
the installation plate until the hooks engage into their
slots(clicking sound).
Tubing holder
Connecting
cable
Drain hose

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents