ADJUSTEMENT TABLE FOR HEATING ENGINEERS
Display on room control module RRG Function
BUM parameter final user level
.
Program
No.
546
ZBreMinL
547
ZReglVerz
551
Kon
552
HydrSystem
553
KonfigHks
555
KonfigRg1
556
KonfigRg2
557
KonfigRg3
558
KonfigRg4
561
KonfigRg7
562
pH2Omin
563
pH2Omax
584
ZkickFkt
596
ZeitAufZu
598
LmodRgVerz
604
LPBKonfigO
605
LPBAdrGerNr
606
LPBAdrSegNr
607
TbwBereit
614
KonfigEingang
615
KonfigAusgang
618
KonfigEingangR
619
KonfigAusgang1R
620
KonfigAusgang2R
621
KonfigAusgang3R
622
TAnfoExtMax
623
PAnfoExtSchwelle
Minimum running time for burner
Control delay after burner startup
Constant for rapid reduction (without
room influence)
Hydraulic system setting Assignment of HKM
or RRG to heating circuit [0...255], see Table 11
Adjustment codes
Adjustment codes
Adjustment codes
Adjustment codes
Adjustment codes
Min. boiler water pressure
Max. boiler water pressure
Time for pump output kick function
Running time for drive in heating circuit 2 (CIM); 30 to 873 s 150 s
Output during control delay time
Adjustment code for bus module CIB
LPB application address for BMU
LPB segment address for BMU
Reduced setting for hot water
Programmable input F2
0 = Standard; 1 = Modem function
2 = Modem function "neg. logic" 3 = Door veil
Programmable output M5
0 = Standard; 1 = Signal output; 2 = Alarm output,
3 = Operating signal, 4 = External transformer
(transformer T2); 5 = M5 (Q2Y2);
6 = DHW circulation pump; 7 = Door veil;
8 = Primary loop pump; 9 = RegC1;
10 = Basic function K2; 11 = DHW loading
function (layer tank only); 12 = Analog threshold
Programmable input on relay module:
0 = Standard (no function); 1 = modemfunction;
2 = modemfunction; 3 = door veil; 4 = temperature
setpoint; 5 = heat output setpoint; 6 = sensor
hydraulic switch
Note: with CISP, only 4 and 5 possible
Function of output 1 relay module
0 = Standard; 1 = Signal output; 2 = Alarm output,
3 = Operating signal, 4 = External transformer
(transformer T2); 5 = M5 (Q2Y2);
6 = DHW circulation pump; 7 = Door veil;
8 = Primary loop pump; 9 = not possible;
10 = Basic function K2; 11 = not possible
12 = Analog threshold
Function of output 2 relay module
Setting as parameter 619
Function of output 3 relay module
Setting as parameter 619
Max. value of heat demand in case of external
temperature setting (if param. 618 = 4)
Switchpoint of the analog threshold
(% of max. value) (if param. 618 = 5)
Basic setting
New
(set at factory)
setting *)
0 s
2)
60 s
4
2
21
00110100
00000000 (not used)
00000100 (not used)
01000000
00001110
0,7 bar (not activated)
2,5 bar (not activated)
2)
5 s
2)
25 %
00010000
1 - -
0 - -
40 °C
0
2
0
3
3
0
100 °C
5 %
33