OPERATING / COMMISSIONING
Fig. 2 Control panel
1
Boiler module
2
Service socket
for service module RRG
(turn to left to open 90°)
Safe temperature
limiter STB
3
Mains switch S1
Commissioning
Fault display (8)
Reset button (7)
Display mode
button (10)
10
6
Burner operation LED
13 Display
G Switch on the mains switch (3) on the boiler module (1). When sufficient
water and gas pressure is present, the Eurocondense Plus can start operating.
G Set the central heating knob of the HKM to the desired boiler temperature
value (without outdoor temperature sensor) or to the desired room temperature
value (if an outdoor temperature sensor is connected). While turning the knob,
the setpoint is displayed.
G Set the hot water knob to the desired hot water temperature value. While
turning the knob, the setpoint is displayed.
G If the summer-/winter switch is set to "Automatic" or "Winter", the
PARAMOUNT starts operating in the heating or DHW mode. If it is set to
"Summer", the PARAMOUNT starts operating in the DHW mode.
Manual summer
LED "Auto"
H
LED "@"
H
G The current boiler temperature is indicated on the display (13) and the green
burner operating LED (6) illuminates when the burner is in operation.
P
Note: If an outdoor temperature sensor is not connected, the Eurocondense Plus
is heated up to a boiler temperature of approx. 55 °C.
G If the burner does not start up, the red fault indicator LED (8) and display (13)
flash with the error code (see Table 13).
P
The Eurocondense Plus can be reset with the Reset button (7) and the burner is
then ready for a new start attempt. After a number of unsuccessful start attempts,
P
inform a heating engineer depending on the error code
present (Table 13).
G With the Display mode button (10), the values (parameters, actual values or
P
nominal values) listed in Table 7 can be checked and changes made.
7
8
P
1)
12 Chimney sweep button S4
Manual winter
LED "Auto"
H
LED "@"
G
Reset button S2
Fault indicator LED
5 Installation for
EMS timer
HKM
Hot water control
Central heating
Auto
Automatic summer/winter
switchover button
9 Temperature LED
10 Display mode butten S3
11 P LED
1) Display of boiler temperature (delivery
state); all other values can be displayed
after calling the parameter (see Table 7).
Automatic mode
LED "Auto"
G
LED "@"
H or G *)