HEATER,
AtR
coNDliloNER
AND vENTilATtoN
-
m,i,"q"*'
ss-21
CONDENSER FAN MOTOR CONTROL RELAY
Check
for
continuity between the terminals when the
battery
power-supply
is
applied
to
terminal (5). and terminal
(3)
is
earthed.
When current flows
Between terminals
1-2
Continuity
When no
current
flows
Between terminals
1-4. 3-5
Continuity
Between terminals
1-2
No continuity
IDLE.UP OPERATION
CHECK
(1) Before inspection
and
adjustment
set
following condition:
o
Engine coolant temperature:
80-90qC
(176-194"F1
o
Lamps,
electric cooling fan and accessories:
Set
to
OFF
.
Transmission:
Neutral
o
Steering
wheel:
Straightforward
(2) Check whether
or not the
idling speed
is the
standard
value.
Standard value: 75O
r/min
NOTE
There is no necessity
to
make an adjustment. because the
idling speed is automatically adjusted by
the
ISC* system.
lf,
however, there occurs
a
deviation
from the
standard
value
for
some
reason. check
the ISC*
system.
(3)
Check
to
be sure that
the idlig speed becomes the standard
value
when the
air conditioner
switch is switched ON
and
the air
conditioner
is
activated.
Sandard value: 85O r./min
NOTE
There is no necessity
to
make an adjustment, because
the
idling speed is automatically adjusted by
the
ISC* system.
lf,
however, there occurs
a
deviation
from the
standard
value
for
some
reason, check
the
ISC* system.
ISC: ldle
Speed Control
;-.: :
l-
:ri.-,ir
-.- i:i'ii:
,.
'9i-r'-
'
'-- .....
.
r..- : :.
:..
t"!i&r9ii',
i:ti:ti
lv3:.,;i
:'..j .i:i.,-.
lSnitet-,:'f
; !..r., -:.!.+-++i.-
r
EIGFOAT
vehicle
in
the
r:1:].
o
16A1077
r=+
Ör''Y--ö
L-T--J
204(XS
@
Mitsubirhi
Motors
Corporation
Apr.
1991
PUft