Auto-Fresh Defrost; Start Conditions For Auto-Fresh; Release Condition Of Auto-Fresh; Outputs During Auto-Fresh - Hitachi RAM-55QH5 Service Manual

Outdoor unit
Hide thumbs Also See for RAM-55QH5:
Table of Contents

Advertisement

AUTO-FRESH DEFROST

During heating operation is stopped, and when auto-fresh condition is established, defrost operation will be performed while
operation is stopped.
Auto-fresh consists of balancing period at start of defrost for [TDF414] seconds
minutes.
(1)

Start conditions for auto-fresh

When all the following conditions are established, auto-fresh is executed:
1
Defrost request signal is present.
2
All indoor units are stopped.
3
15 minutes of auto-fresh inhibit period has elapsed.
4
Compressor is ON when operation is stopped.
5
Compressor delay command is sent from indoor unit when operation is stopped.
(2)

Release condition of auto-fresh

If any one of following conditions is established, auto-fresh is released:
1
Heat exchange temperature returns (heat exchange temperature ≥ DEFOFF)
2
12 minutes of defrost MAX time has elapsed.
3
Failure occurred.
4
Either unit 1 or unit 2 or unit 3 started operation.
Released during start of balancing period : Stopped or started after remaining balancing period has elapsed.
Released during reverse cycle period : Stopped or started after balancing for 3 minutes.
(3)

Outputs during auto-fresh

[Indoor unit defrost request]: Transmitted only to unit to which auto-fresh is applied (indoor unit stopped last).
[Compressor]: Accelerated by DFSTEP min
[Electric expansion valve]:
Unit auto-fresh not applied: FULL CLOSE when balancing for 30 seconds has elapsed at start of defrost.
Unit auto-fresh applied : Synchronized with step-up of rotation speed of compressor, opened by [DFSPPS] pulses and
(4)
Note
Shifted to auto-fresh in defrost mode when operation is stopped.
All indoor units must be stopped to fulfill condition for auto-fresh.
If signal is delayed, auto-fresh condition will not be established.
Defrosting signal
Unit 1
Unit 2
Unit 1
Unit 2
Unit 1
Unit 2
Turns on for
cooling
Cooling output
Heating output
Outdoor fan
Auto-fresh inhibit period 15min.
WMAX3
Compressor
rotation speed
520
480
Unit 1
0
520
480
Unit 2
0
-1
/TDFSPT seconds and reaches defrost MAX speed [DEFMAX].
reaches MAX opening degree [DEFSMX] when rotation speed of compressor reaches [DEFMAX].
15sec.
Balancing period [TDF414] sec.
WMAX2
WMAX1
30sec.
Defrosting request
Reverse cycle period (max. 12 minutes)
Defrosting sequence
30sec.
TSKTM2
DFSTEP min
TDFSPT sec.
SDRCT2
Hold
DFSPPS$ Pulse
DFCTPS$
Hold
– 65 –
Reverse cycle period for MAX 12
MODEL RAM-55QH5
Balancing request
Balancing request
Balancing period 3min.
DEFMAX
-1
/
80sec.
DFPSMX$
30sec.

Hide quick links: