Auto Swing Function - Hitachi RAS-07BH1 Service Manual

Table of Contents

Advertisement

AUTO SWING FUNCTION

INPUT SIGNAL
OPERATION
STOP
KEY INPUT
DURING
OPERATION
INTERNAL FAN
ON
(THERMO. ON)
DURING
OPERATION
INTERNAL FAN
OFF
(THERMO. OFF)
MAIN SWITCH
STOP
ON
DURING
MAIN SWITCH
OPERATION
OFF
DURING
CHANGE OF
OPERATION
OPERATION
PRESENT CONDITION
OPERATION MODE
AIR DEFLECTOR
STOP
EACH MODE
DURING ONE SWING
AUTO COOL
COOL
STOP
FAN
AUTO DRY
DRY
DURING SWINGING
STOP
AUTO HEAT
HEAT
DURING SWINGING
TEMPORARY STOP
AUTO DRY
DRY
AUTO HEAT
DURING SWINGING
HEAT
COOL
STOP
FAN
DURING ONE SWING
DRY
STOP
CIRCULATOR
DURING ONE SWING
STOP
DURING SWINGING
EACH MODE
DURING
INITIALIZING
STOP
EACH MODE
DURING SWINGING
OPERATING SPECIFICATION
ONE SWING (CLOSING AIR DEFLECTOR)
1 DOWNWARD
2 UPWARD
STOP AT THE MOMENT.
START SWINGING
1 DOWNWARD
2 UPWARD
3 DOWNWARD
STOP AT THE MOMENT.
START SWINGING
1 DOWNWARD
2 UPWARD
3 DOWNWARD
STOP AT THE MOMENT.
START SWING AGAIN.
STOP SWINGING TEMPORARILY.
(SWING MODE IS CLEARED IF SWING COMMAND IS
TRANSMITTED DURING TEMPORARY STOP.)
INITIALIZE
1 DOWNWARD
2 UPWARD
INITIALIZE
1 DOWNWARD
ONE SWING (CLOSING AIR DEFLECTOR)
1 DOWNWARD
2 UPWARD
INITIALIZING CONDITION OF EACH MODE.
STOP SWINGING AND MODE BECOMES INITIALIZING
CONDITION.
REFERENCE
INITIALIZE AT NEXT
OPERATION.
INITIALIZE AT NEXT
OPERATION.