Video System Adjustments; 28 Mhz Origin Oscillation Adjustment (Vc-195 Board); Afc F0 Adjustment (Vc-195 Board) - Sony Handycam CCD-TR311 Service Manual

Video camera recorder; video camera recorder
Hide thumbs Also See for Handycam CCD-TR311:
Table of Contents

Advertisement

3-4.

VIDEO SYSTEM ADJUSTMENTS

Video system adjustments must be performed in the following order.
[Adjusting Order]
1. 28MHz origin oscillation adjustment
2. AFC f0 adjustment
3. Filter f0 adjustment
4. Y OUT level adjustment
5. C OUT level adjustment
6. RP filter f0 adjustment
7. Hi8 REC Y current adjustment
8. Standard REC Y current adjustment
9. Hi8 REC L level adjustment
10. Standard8 REC L level adjustment
11. REC C current adjustment

1. 28 MHz Origin Oscillation Adjustment (VC-195 board)

Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Mode
VTR stop
Signal
No signal
Pin ^§ of IC202 or pin !™ of IC501
Measurement Point
Measuring Instrument Frequency counter
Adjustment Page
F
Adjustment Address
2C
Pin ^§ of IC202 :
Specified Value
f=3579545±17Hz (NTSC)
f=4433618.75±17Hz (PAL)
Pin !™ of IC501 :
f=14318181±68Hz (NTSC)
f=14187500±55Hz (PAL)
Note 1: NTSC MODEL: CCD-TR311
PAL MODEL:
CCD-TR311E/TR411E/TR412E/
TR511E/TR512E/TR640E/TR730E/
TR840E/TR845E
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 41, and press the PAUSE
button of the adjusting remote commander.
3) Select page: 2, address: 61, and set data: 30.
4) Select page: F, address: 2C, change the data and set the clock
frequency(f) to the specified value.
5) Press the PAUSE button of the adjusting remote commander.
6) Select page: 2, address: 61, and set data: 10.
7) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.

2. AFC f0 Adjustment (VC-195 board)

Adjust the pull-in range of the A/D converted clock generator during
playback.
Mode
Signal
Measurement Point
Measuring Instrument Digital voltmeter
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 3, address: 01, set data: 4D, and press the PAUSE
button of the adjusting remote commander.
3) Select page: F, address: 4A, change the data and set the DC
voltage (A) to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: 3, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
6) Select page: 0, address: 01, and set data: 00.
5-41
VTR stop
No signal
Pin 4 of CN910 (AGC f0)
F
4A
A = 2.10±0.05Vdc