Daikin MC707VM-S Manual page 35

Photocatalytic air purifiers
Hide thumbs Also See for MC707VM-S:
Table of Contents

Advertisement

Troubleshooting
6.2.5 LED automatically operates.
Caution
1
Models Covered
MC707VM-S
MC707VM-W
2
Method of Mal-
function Detection
3
Malfunction Deci-
sion conditions
4
Supposed Causes
Malfunction (demo mode)
The reset switch is blocked.
34
Be sure to turn off power switch before connect or disconnect connector,
or parts damage may be occurred.
5
Troubleshooting
Diagnosis
LED may be in demo mode.
Exit demo mode.
Unplug unit or
turn off power.
Restart.
No
Does unit beep after 3
seconds?
Yes
SiBE81-623A
Remedy
*Entering demo
mode
Keep holding down
reset switch and
turn on power.
Demo mode is
exited.
The unit is in demo
mode as reset
switch is blocked.
Check it.