Operation Manual
Care and Cleaning
3. Remove the bio-antibody filter.
• Remove the bio-antibody filter from hooks (2 locations) at top of
the plasma ionizer.
Top hooks (2 locations)
Bio-antibody filter
4. Remove the plasma ionizer.
• Holding the handle, lift towards yourself and remove from the top
2 hooks.
Plasma ionizer
5. Remove the opposing pole plates at back of the plasma
ionizer.
• Open the knob of the ionizer frame and hold up the opposing pole
plate to remove.
Be careful not
to catch in the
internal ionizer
wires.
Ionizing frame
6. Remove the streamer discharger.
• Insert your finger into the hole on top (hole with
then gently pull up the streamer discharger.
Streamer discharger
11
22
Hooks
(one left and one right)
It is easier to
remove if lifted
from outside.
Knob
Opposing
Open
pole plate
Ionized wire
mark) and
Clean the plasma ionizer
(If "cleaning sign" on the main unit display blinks)
Blink
CAUTION
Stop operation before cleaning and be careful not to cut your hands
with the opposing pole plate or ionizer wires.
(It is safer to use rubber gloves.)
Plasma ionizer
1) Ionizing frame
2) Ionized wire
CAUTION
There are ionizer wires at back of the opposing pole
plate. When attaching or removing, be careful not to cut
them.
• "Cleaning sign" blinks if operated while the ionizer wires are cut.
The dust elimination efficiency deteriorates while the sign is
blinking.
• If the ionizer wires should be cut, replacement is necessary.
Contact your dealer.
SiBE81-623A
3) Streamer discharger
4) Opposing pole plates