e_ka250.book Page 6 Tuesday, September 5, 2006 4:10 PM
INTRODUCTION
Operating Precautions
• In order to ensure that this unit serves you longer, avoid
storing or using in the following.
Extremely hot or cold places
Strong vibrations
Dusty places
High humidity
Near loud noise sources
• Do not subject this unit to strong vibration or impact when
installing or moving it.
• Do not plug in or unplug the camera cable connector when
this unit is powered on.
• Use only the designated power supplies. Use either RM-
P210 or IDX IA-60a, VL-2PLUS.
• To reduce power consumption, turn off the power when
not in-use.
• When a transceiver or mobile phone is used near this unit,
noise may occur in the intercom speaker or the screen.
This is not a malfunction.
• Grounding the INTERCOM G (GND) terminal is recom-
mended as noise may be induced depending on the inter-
com headset used.
• Use only the specified standard length camera cable. Oth-
erwise, cable compensation may be insufficient.
CAUTION
• Moving this unit with the supporting tripod attached may
cause it to detach and fall if there is a sudden external
impact or vibration. This may cause injuries. Remove this
unit from the tripod before moving it.
• The front base mount may lock even when the pin on this
device and the rear base mount attachment hole on the
camera is not attached. After attaching, confirm that the
camera has been firmly attached. The camera may fall
and cause injury or accident if it is not attached properly.
• When transporting with the camera attached to this
device, hold the bottom of this device. If transported with
the camera handle, the attachment may come off and
this device may fall and cause injury or accident.
6
Regarding Genlock Signal and
Adjustment of System Phase
When using the RM-P210 Remote Control Unit with this sys-
tem, input Genlock signal into either the GY-HD250 Camera
or RM-P210.
However, if Genlock signal is applied to both GY-HD250 and
RM-P210, screen images will appear choppy.
Perform System Phase adjustment on the machine where
Genlock signal has been input.
In addition, RM-LP55 is prioritized when connected.
• When Genlock signal is input into RM-P210
Adjust the phase by adjusting RM-P210's H and SC.
Use RM-LP55 to adjust the phase if it is connected to this
system.
• When Genlock signal is input into GY-HD250
• Adjust the phase by adjusting GY-HD250 H and SC.
(Adjustment should be performed through GY-HD250
even if RM-P210 is connected.)
Use RM-LP55 to adjust the phase if it is connected to this
system.
How to Use This Manual
Characters and symbols used in this manual
CAUTION : Points to pay attention to during operation.
NOTE
: Details for reference, such as functions or
constraints during use.
X
: Pages or items to refer to.
Notation used in this manual
• The copyright for this manual is property of JVC. Unau-
thorized reproduction or publication of this manual in
part or in whole is strictly forbidden.
• All product names that appear in this document are the
trademarks or registered trademarks of their respective
companies.
Marks and symbols such as
in this document.
• The design, specifications, etc. found in this manual are
subject to change without notice for improvement.
• This manual refers to the connecting camera as GY-
HD250. However, the same operations are used when
connecting the GY-HD251.
™
®
©
,
and
do not appear