Auger Engagement; Initial Start Up, Checks & Adjustment Instructions - Cornelius IMD300-15A Installation Manual

Imd series countertop ice maker
Hide thumbs Also See for IMD300-15A:
Table of Contents

Advertisement

A
E
UGER
NGAGEMENT
Be certain that auger is fully engaged to lower drive and that extruding head is fully engaged to evaporator.
I
S
U
NITIAL
TART
P
NOTE: Do not start unit before completing above Installation Instructions.
Turn on water supply and main power switch (located on top of electric box). All IMD 30 lb. and 90 lb. series units
are equipped with a 45 second delay timer. This means that the refrigeration system will not start until 45 seconds
of dispense are accumulated in the timer. Start the refrigeration system by depressing the ice dispense button for
45 seconds. Make the following system checks:
NOTE: If unit will not start be sure water reservoir is full. Low water safety control must be properly
adjusted to start and shut down unit. If water level drops below bottom of reservoir, unit must
shut down. Adjustment is made by moving magnet up or down.
Water Level - If necessary, adjust float by bending float arm up or down as needed. Push float assembly down until
unit stops running. Release float and unit will restart. Keep water in reservoir at level line while unit is in operation.
See Figure 4.
Low Water Safety Control - Adjust magnet by bending magnet arm as shown in Figure 4 to shut down unit if the
water level drops below the line on the side of the reservoir.
Bin Control - Remove four screws from top of bin cover and lift cover so bin control plate can be manually lifted
until unit shuts down. Release plate and unit will restart (on IMD300-30, IMD600-30, and IMD600-90 the dispense
button must be depressed for 45 seconds before unit will start). Replace screws.
Dispense Switch and Mechanism - By depressing the dispense switch, the dispense mechanism door on the
storage bin will open, and chain, sprockets, and agitator will rotate counterclockwise.
NOTE: If any of these checks or adjustments cannot be achieved, refer to Troubleshooting Section of
this manual or call our Technical Support Center for assistance at 1-800-238-3600.
© 2004-2015, Cornelius Inc.
, C
& A
HECKS
DJUSTMENT
Figure 4. Float Assembly
Countertop Icemaker IMD Series Installation Manual
I
NSTRUCTIONS
- 7 -
Publication Number: 638085277INS