Function
4.13 Black Box Function
This function saves data immediately before the error occurs in ODU main PCB, and thus making error analysis
cause possible.
I Saving process : Making Data ➠ Save EEP data ➠ data saving place select ➠ file save
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Data Loading Method
IDU, ODU stop
Press the black button (5 sec.)
➠
EEPROM
Main Micom data Loading
Yellow LED(LED01C) stops when data is loading
After completion, it is starts blinking (about 20 sec.).
EEPROM data save to PC by using
<Save EEP data> in LGMV