8400 Starting Watts/6750 Rated Watts (LPG) Electric Start DUAL FUEL GENERATOR MODEL NUMBER 71531 12039 Smith Ave. SAVE THESE INSTRUCTIONS Santa Fe Springs CA 90670 Important Safety Instructions USA / 1-877-338-0999 MADE IN CHINA are included in this manual. REV 71531-20140505 www.championpowerequipment.com...
Page 2
AN IMPORTANT MESSAGE ABOUT TEMPERATURE: Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40°C (104°F). When your product is needed your product may be operated at temperatures ranging from -15°C (5°F) to 50°C (122°F) for short periods.
ENGLISH INTRODUCTION Introduction Accessories Congratulations on your purchase of a Champion Champion Power Equipment manufactures and sells Power Equipment generator. CPE designs and builds accessories designed to help you get the most from your generators to strict specifications. With proper use and purchase.
Please call our help line at 1-877-338-0999 situation which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. REV 71531-20140505...
Traumatic amputation or severe laceration can result. Keep hands and feet away from rotating parts. Tie up long hair and remove jewelry. Operate equipment with guards in place. DO NOT wear loose-fitting clothing, dangling drawstrings or items that could become caught. REV 71531-20140505...
Page 7
Inform your electricity provider immediately if you or anyone in your household depends on electrical equipment to live. Inform your electrical provider immediately if a loss of power would cause you or anyone in your household to experience a medical emergency. REV 71531-20140505...
– Always keep the LPG cylinder in an upright position. – LPG will burn skin if it comes in contact with it. Keep any and all LPG away from skin at all times. REV 71531-20140505...
Power Panel – See “Power Panel” section. Air Cleaner – Protects the engine by filtering dust Fuel Selector Switch – Used to select fuel source. and debris from the intake air. Recoil Starter – Used to manually start the engine. LPG Hose Connector REV 71531-20140505...
(NEMA 5-20R) – May be used to supply electrical Ground Terminal – Consult an electrician for local power for the operation of 120 Volt AC, 20 Amp, grounding regulations. single phase 60 Hz electrical loads. (10) Circuit Breakers REV 71531-20140505...
71531 ENGLISH CONTROLS AND FEATURES Parts Included Your 71531 Dual Fuel Generator ships with the following parts: Wheel Kit – 9.5 in. (24.1 cm) Wheel ....
2. Slide the M10x120 wheel bolt through the washer, bushing and wheel. 3. Slide the bolt through the mount point on the frame. 4. Fasten securely with the M10 lock nut. 5. Repeat steps 2-4 to attach the second wheel. REV 71531-20140505...
2. Remove oil fill cap/dipstick to add oil. 3. Add 1.2 qt. (1.1 L) of oil (included) and replace oil fill cap/dipstick. DO NOT OVERFILL. 4. Check engine oil level daily and add as needed. REV 71531-20140505...
DO NOT fill fuel tank indoors. DO NOT fill fuel tank when the engine is running or hot. DO NOT overfill the fuel tank. DO NOT light cigarettes or smoke when filling the fuel tank. REV 71531-20140505...
We strongly recommend that you consult with a qualified – Always position the cylinder so the connection electrician to ensure compliance with local electrical codes. between the valve and the gas inlet won’t cause sharp bends or kinks in the hose. REV 71531-20140505...
During operation the muffler and exhaust fumes produced will become hot. If adequate cooling and breathing space are not supplied, or if the generator is blocked or contained, temperatures can become extremely heated and may lead to fire. REV 71531-20140505...
Next pull the The fuel selector is locked into place once a starter cord slowly until resistance is felt and then pull “CLICK” sound is made. Only then can a fuel valve rapidly. be turned to the vertical position. REV 71531-20140505...
If the generator will be connected to a building electrical system, consult your local utility company or a qualified electrician. Connections must isolate generator power from utility power and must comply with all applicable laws and codes. REV 71531-20140505...
To alleviate high altitude issues other than the natural 5. Plug in and turn on the next item. power loss, Champion Power Equipment can provide a 6. Allow the engine to stabilize. high altitude carburetor main jet. The alternative main 7.
6. Dispose of used oil at an approved waste 5. Squeeze in a clean, absorbent cloth to remove all management facility. excess oil. 6. Place the filter in the assembly. 7. Reattach the air filter cover and snap in place. REV 71531-20140505...
Contact our helpline at 1-877-338-0999 to locate the 3. Remove the spark arrester screen. nearest Champion Power Equipment certified service 4. Carefully remove the carbon deposits from the spark arrester screen with a wire brush. dealer for your generator or engine maintenance needs.
Ignition Switch, the NOTE Fuel Valve and the Battery Switch are set in the the the OFF position and the battery leads have A Float Charger will maintain the battery condition been disconnected from the battery. over long storage periods. REV 71531-20140505...
Review load and adjust. See “Power Management” Faulty cords or device Check for damaged, bare or frayed wires. Replace defective device For further technical support: Technical Service Mon – Fri 8:30 AM – 5:00 PM (PST/PDT) Toll Free: 1-877-338-0999 tech@championpowerequipment.com REV 71531-20140505...
Warranty Qualifications Other Exclusions Champion Power Equipment (CPE) will register this This warranty excludes: warranty upon receipt of your Warranty Registration Card – Cosmetic defects such as paint, decals, etc.
Page 31
The United States Environment Protection Agency (U.S. EPA.) and the California Air Resources Board (CARB) Emission Control System Warranty Your Champion Power Equipment (CPE) engine complies with both the U.S. EPA and state of California Air Resources Board (CARB) emission regulations.
Page 32
EMISSION CONTROL SYSTEM WARRANTY The following are specific provisions relative to your Emission Control System (ECS) Warranty Coverage. 1. APPLICABILITY: This warranty shall apply to 1995 and later model year California small off-road engines (for other states, 1997 and later model year engines). The ECS Warranty Period shall begin on the date the new engine or equipment is delivered to its original, end-use purchaser, and shall continue for 24 consecutive months thereafter.
Page 33
You must take your CPE engine or the product on which it is installed, along with your warranty registration card or other proof of original purchase date, at your expense, to any Champion Power Equipment dealer who is authorized by Champion Power Equipment, Inc. to sell and service that CPE product during his normal business hours.