Yamaha YP250R 2005 Service Manual page 336

Table of Contents

Advertisement

2. Voltage
• Connect the pocket tester (DC 20 V) to the
meter assembly coupler as shown.
Positive tester probe → brown 1
Negative tester probe → black 2
G/L
B
Dg
• Set the main switch to "ON".
• Measure the voltage (DC 12 V) of brown
1 and black 2 at the meter assembly
coupler.
• Is the voltage within specification?
YES
Replace the meter
assembly.
Y
Sb
O/W
Br/G
Br/G
Ch
Gy/R
B
G/R
Gy/B
Gy Br
R/L
2
1
NO
The
wiring
circuit
from the main switch
to the meter assem-
bly coupler is faulty
and
must
repaired.
SIGNALING SYSTEM
be
8 - 42
+