Verifying Proper Operation

Make sure that power to the electrical outlet is turned
off at the circuit breaker or fuse box and that the gas is
turned off at the gas supply valve before proceeding.
Verify that the power supply meets the specifications on
page 3 before proceeding.
The cooktop must be properly grounded at all times when
electrical power is applied.
Prior to operating the cooktop, read the accompanying use
and care manual carefully.
1.
Make sure all the cooktop burner controls are in the
OFF position.
2.
Connect the power cord to the electrical outlet.
3.
Turn on power to the electrical outlet at the circuit
breaker or fuse box.
ON
Burner normally
lights when knob
reachs this
position
HIGH
position
Area of
operation
Single Burner Control Knob
NOTE: If the cooktop does not operate properly, follow these troubleshooting steps:
Verify that power and gas are supplied to the cooktop.
Check to make sure that the power plug is connected to the electrical outlet and that power is turned on at the circuit
breaker or fuse box.
Check to make sure that the burners are properly seated.
If the burner continues to spark after ignition without stopping, have a licensed electrician check the electrical outlet
for proper grounding or reversed polarity.
Repeat the above burner ignition test.
If the appliance still does not work, do not attempt to repair the appliance yourself. Contact the Dacor Customer Service
Team at (800) 793-0093.
8
Installation Instructions
WARNING
Knob position
indicator
LOW
position
4.
Depress and turn one burner control knob at a time
slowly counterclockwise to the HIGH position. Verify
that the associated burner igniter sparks, then return
the knob to the OFF position. Repeat for all of the
remaining control knobs.
5.
Turn on the gas supply valve.
6.
Perform the following ignition test for all of the burners:
Press and turn the control knob
clockwise to the HIGH position. Only the selected
burner will spark. It may take up to four seconds
for the burner to ignite, at which time the igniter
will stop sparking. If ignition does not occur within
four seconds, turn off the knob, wait for at least two
minutes to allow any gas to dissipate, then repeat
the test.
Once the burner lights, the control knob can be
rotated counterclockwise from HIGH to LOW to
adjust the flame height progressively. On dual burn-
ers turn the control knob to the simmer setting and
make sure the low level flame can be adjusted.
When the unit is installed properly, the flame will
be steady. It will also have a sharp, blue inner cone
that will vary in length proportional to the burner
size.
Burner normally
ON
lights when knob
reachs this
position
HIGH
position
Area of
operation
LOW
position
Dual Burner Control Knob
slowly counter-
Knob position
indicator
LOW
position
Area of
operation
HIGH
position

Advertisement

Table of Contents
loading

This manual is also suitable for:

Preference rgc365

Table of Contents