LTS 40-250 SERIES — TYPICAL LAYOUTS
Straight
U Shape
L Shape
Z Shape
EMITTER LENGTH
MODEL
Min.
LTS 40
15 Ft.
LTS 50
15 Ft.
LTS 60
20 Ft.
LTS 75
20 Ft.
LTS 80
30 Ft.
LTS 90
30 Ft.
LTS 100
30 Ft.
LTS 110
30 Ft.
LTS 120
30 Ft.
LTS 125
30 Ft.
LTS 130
30 Ft.
LTS 140
40 Ft.
LTS 150
40 Ft.
LTS 160
40 Ft.
LTS 175
40 Ft.
LTS 180
50 Ft.
LTS 200
50 Ft.
LTS 225
50 Ft.
LTS 250
50 Ft.
NOTES:
1)
In all configurations, the control unit must be connected directly to either a) the 24-hole flange of the 10 ft. aluminized
steel start/end body section (for LTS 40-200 models) or b) the 6-hole flange of the 10 ft. Alumi-Therm starting body
section (for LTS225 and LTS250 models). Failure to attach the control box to the 6-hole flange for LTS225-250 as
indicated above will void the manufacturer's warranty.
2)
Joining of two 90º elbows directly together to form a "Z" shape IS NOT permitted.
3)
5 Ft. Body Packages may be utilized on any of these heaters to yield heater lengths from 50 ft. to 80 ft.
4)
Any configuration of components not shown in the illustrations may be used except as noted in 1 and 2 above.
Max.
20 Ft.
30 Ft.
30 Ft.
30 Ft.
40 Ft.
40 Ft.
40 Ft.
40 Ft.
40 Ft.
50 Ft.
50 Ft.
50 Ft.
50 Ft.
50 Ft.
50 Ft.
80 Ft.
80 Ft.
80 Ft.
80 Ft.