CLEARANCES TO COMBUSTIBLES (UL AND ULC)
BACKWALL / SIDEWALL
A
B
CORNER INSTALLATION
E
INSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove Top
SINGLE WALL PIPE
with TOP SHIELD or
Step-Top Model
DOUBLE WALL PIPE
with TOP SHIELD or
Step-Top Model
INSTALLATION: 90° Elbow Off Top of Stove Through Backwall
SINGLE WALL PIPE
with TOP SHIELD or
Step-Top Model
DOUBLE WALL PIPE
with TOP SHIELD or
Step-Top Model
INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed
factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of
Alcove shall be no more than 48"(1220mm) with a minimum height of 48" (1220mm) to top of unit, and the referenced clearances.
*In Canada must comply with CAN/ULC-S269 M87 for the 650
DOUBLE WALL PIPE
with TOP SHIELD or
Step-Top Model
INSTALLATION: ALCOVE WITH PROTECTED SURFACES. Maximum depth of Alcove shall be no more than 48" (1220mm) with a
minimum height of 48" (1220mm) to top of unit, except as noted below, and the referenced clearances.
COMBUSTIBLE MATERIAL FACED WITH 3-1/2" BRICK
SINGLE WALL PIPE
with TOP SHIELD or
Step-Top Model
DOUBLE WALL PIPE
with TOP SHIELD or
Step-Top Model
COMBUSTIBLE MATERIAL FACED WITH 3-1/2" BRICK PLUS 2" CLEARANCE TO COMBUSTIBLE
SINGLE or DOUBLE
WALL PIPE
Any Top or SHIELD
Configuration
*NFPA MINIMUM CLEARANCE - NOT TESTED
***NFPA 211 Section 9-6.2.1: "After reduction, clearance shall be not less than 12" (305 mm) from the
appliance to combustible unless tested..."
250-6103C December 6, 2004
3100 ACT Wood Stove Series
90° OFF TOP
UP & OUT CEILING
C
CLEARANCE
D
STOVE TO CEILING
CLEARANCE
F
E
REDUCED REAR CLEARANCE ACCESSORY:
F
Top Shield Part 831-0972
(clearances equal those of Step-Top Model)
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)
NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
A
B
15 (381)
12.5 (318)
12 (305)
9.5 (241)
11 (279)
8.5 (216)
9 (228)
6.5 (165)
12 (305)
9.5 (241)
10 (254)
7.5 (191)
8 (203)
5.5 (140)
8 (203)
5.5 (140)
12 (305)
9.5 (241)
10 (254)
7.5 (191)
14.5 (368) 12 (305)*** 23.5 (597) 14.5 (368)
10 (254)
7.5 (191)
12 (305)
9.5 (241)
10 (254)
7.5 (191)
8 (203)
5.5 (140)
*
H
G
C
D
E
24 (610)
15 (381)
8.5 (216)
22 (559)
13 (330)
6 (152)
22.5 (572) 13.5 (343)
7 (178)
20.5 (521)
11.5 (292)
4.5 (114)
22 (559)
13 (330)
8.5 (216)
19.5 (495) 10.5 (267)
6 (152)
17.5 (445)
8.5 (216)
7 (178)
16.5 (419)
7.5 (191)
4.5 (114)
o
C Factory-built chimney.
23.5 (597) 14.5 (368)
N/A
20.5 (521) 11.5 (292)
N/A
N/A
21 (534)
12 (305)***
N/A
21 (534)
12 (305)***
N/A
20.5 (521) 11.5 (292)
N/A
14 (356)
5 (127)*
N/A
** SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED
ALCOVE SIDE VIEW
G
A
B
ALCOVE TOP VIEW
C
D
F
G
H*
17 (432)
48 (1220)
18 (457)
14.5 (368)
48 (1220)
18 (457)
15.5 (394)
48 (1220)
**
13 (330)
48 (1220)
**
17 (432)
48 (1220)
18 (457)*
14.5 (368)
48 (1220)
18 (457)*
15.5 (394)
48 (1220
**
13 (330)
48 (1220)
**
N/A
48 (1220)
**
N/A
48 (1220)
**
N/A
48 (1220)
18 (457)*
N/A
48 (1220)
18 (457)*
N/A
48 (1220)
*
N/A
48 (1220)
*
N/A
24 (610)
**