Ash Removal System - Quadra-Fire 3100 Series Operating & Maintenance Instructions

Advanced combustion technology (act)
Table of Contents

Advertisement

ASH REMOVAL SYSTEM (ARS) INSTALLATION
1. Place protective pad or stove pallet on floor.
2. Lay body of stove on its back on protective pad or pallet.
3. Remove ash removal system top and bottom cover plates
by loosening nuts under stove. Discard both plates
STOVE BOTTOM
4. Using a rubber mallet, install plugs (supplied) into two front
holes, See Figure 15A.
5. Line up holes in ash removal system with holes in adapter
on bottom of stove.
6. Screw ash removal system securely in place.
7. Insert ashpan into ash removal system box, making sure
the overhanging lip is facing towards you.
8. Attach legs or pedestal. (See instructions on page 16).
NOTE LEG MODELS: DO NOT TILT THE UNIT ON THE
CAST IRON LEGS. Lift the unit upright and place it into
position on the floor protector.
9. After righting stove, insert ash removal system grate into
opening in firebox floor.
INSTALL PLUGS
INTO THESE TWO
HOLES
250-6103C December 6, 2004
3100 ACT Wood Stove Series
GRATE
TOP COVER
PLATE
NUTS
FIGURE 15A
ARS OPERATING AND CLEANING
1. When stove is cool, open front door and brush most
of the ash into the center of the firebox. Remember
to leave 1/4" to 1/2" (6-13mm) of ash on the firebox
floor to act as a natural grate, allowing air to flow
.
freely underneath wood.
2. Clean ash down through the ash removal system
grate into the drawer below. If there are large pieces
in the ashes, you can remove the grate before
brushing the ash into the drawer. Be sure to replace
the grate before operating the stove.
3. Swing open ash removal door on leg model. (On the
pedestal model, first pull down the hinged pedestal
front to expose the ash removal door).
4. Pull out the ash drawer. CLOSE the ash removal
door. (Closing this door avoids ash blowing into the
room in the event of a downdraft).
5. Empty the ashes following the directions below.
6. Swing open ash removal door and replace ash
drawer with the overhanging lip facing toward you.
7. Close ash removal door securely.
Disposal of Ashes. Ashes should be placed in a metal
container with a tight fitting lid. The closed container
of ashes should be placed on a noncombustible floor
or on the ground, well away from all combustible
materials, pending final disposal. If the ashes are
disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.
LEG MODEL
PEDESTAL MODEL