Quadra-Fire 3100 Series Operating & Maintenance Instructions page 18

Advanced combustion technology (act)
Table of Contents

Advertisement

R
Included in Kit: 1 front cover; fiberglass rope; 2 vent
straps; venting flange & 4 screws; termination
cap & screws. Not all materials are needed for
each model.
Items Needed for Installation: 4" (102mm) flex pipe
in the length as required for your installation;
Phillips screwdriver; Silicone sealant; Drills and
saws necessary for cutting holes through the wall
or flooring in your home.
1. Remove all materials from packing box.
2. Using a #2 Phillips screwdriver, remove 2 bolts
beneath the ashcatcher. Re-use bolts to install front
cover. Be certain that the cover is pushed back as
far as possible.
3. Install side covers to each side. Slide covers into
area and secure with 4 sheet metal screws.
4. Floor installation: Cut a 4" (102mm) minimum
hole in the floor to accommodate outside air piping.
Use 4" (102mm) metal flex or rigid piping to directly
connect outside air to the unit or into vented crawl
space. (Do not put flex into a non-vented crawl
space). Use the supplied termination cap with a
rodent screen. Seal between the floor and the
pipe with silicone to prevent moisture penetration.
Install fiberglass sealing rope under each side
of pedestal.
5. Rear/wall installation: (Millennium Model only,
use the knockout plate in rear of the pedestal for
exterior wall venting.) Cut a 4" (102mm) hole in
outside wall to accommodate outside air piping.
Use 4" (102mm) metal flex or rigid piping to directly
connect outside air to stove intake. Use the
supplied termination cap with a rodent screen.
Seal between the wall and the pipe with silicone
to prevent moisture penetration. Install fiberglass
sealing rope under each side of pedestal.
Page 18
3100 ACT Wood Stove Series
OUTSIDE AIR KIT INSTALLATION
Part 831-1780
FRONT
COVER
FIBERGLASS
SEALING
ROPE
FRONT
COVER
FRONT COVER
SIDE COVER
(2)
FIBERGLASS SEALING ROPE
4" (102mm) FLEX LINE
(Not Included)
UNI-BODY
PEDESTAL MODEL
(Cut-away
view)
FLEX
SIDE
FLANGE
COVER (2)
OUTSIDE AIR TERMINATION CAP
(contains rodent screen)
UNI-BODY LEG MODEL
FLEX
FLANGE
SIDE
COVER (2
)
250-6103C December 6, 2004
FLEX FLANGE
(if needed for rear exit.)
C L
4-3/8" (111mm)
OUTSIDE AIR
TERMINTATION CAP
(contains rodent screen)
4" (102mm) FLEX LINE
(Not Included)
4" (102mm) FLEX LINE
(Not Included)
OUTSIDE AIR TERMINATION
CAP
(contains rodent screen)

Advertisement