Thor Motor Coach Class B+ Owner's Manual page 66

Thor motor coach recreational vehicle
Table of Contents

Advertisement

1. Completely retract the slide out.
2. Allow the motors to amp out and hold the switch for an additional 3-5 seconds.
3. Extend the slide out anywhere from 2-4 inches (enough to break the seal) and
stop.
4. Retract slide out again allowing the motors to amp out and holding the switch for
3-5 seconds.
5. Repeat this 3 times.
6. On the 4th time, FULLY extend the slide out and hold the switch until the motors
amp out and for an additional 3-5
7. FULLY retract the room and hold the switch until the motors amp out and for an
additional 3-5 seconds.
During operation when an error occurs the board will use the leds to indicate where
the problem exists. For motor specific faults the green LED will flash once for
Motor 1, and two times for Motor 2. The red LED will flash from two to nine times,
depending on the error code.
The error codes are as follows:
2. Battery drop out: Battery capacity low enough to drop below 6 volts while
running.
3. Low battery: Voltage below 8 volts at start of cycle.
4. High battery: Voltage greater than 18 volts.
5. Excessive motor current: High amperage, also indicated by 1 side of slide
continually stalling.
6. Motor short circuit: Motor or wiring to motor has shorted out.
8. Hall signal not present: Encoder is not providing a signal. Usually a wiring
problem.
9. Hall power short to ground: Power to encoder has been shorted to ground.
Usually a wiring problem.
When an error code is present, the board needs to be reset. Energizing the extend/
retract switch resets the board. Energize the extend/retract switch again for normal
operation.
Controls and Operations
Timing the Schwintek
slide out system
Controller
Error Codes