repeat the measurement and then transmit it.
Selecting particular values in the
display
By using the Min. / Max. function particular measure-
ments can be selected for transmission. The display
shows a number of measurements (min., max., last
measurement taken). You can select a particular
measurement by using a longer press on the PLUS -
key {A, 3} or a longer press on the MINUS - key
{A, 13}. When selected the measurement blinks.
Once selected and blinking, the measurement can be
transmitted using the BLUETOOTH
The same selection process can be used for areas,
volumes, indirect measurements and room dimen-
sions.
Transmission of user-entered mea-
surements
A measurement on the display can be changed if you
wish. By pressing the EQUAL - key {A, 5} the value
blinks and can then be changed using the PLUS - key
{A, 3} and the MINUS - key {A, 13}. Pressing the keys
for longer increases the rate of change. Pressing the
EQUAL - key {A, 5} again confirms the change and
the value can be transmitted as normal.
NOTE
The free software supplied is designed to
provide the user with basic functionality. Leica
Geosystems provides no warranty for this free soft-
Leica DISTO™ A6 1.1.0 gb
ware and offers no support for it. Leica Geosystems
accepts no liability whatsoever arising from the use
of the free software and is not obliged to provide
corrections nor to develop updates or upgrades.
You can find numerous commercial vendors of soft-
ware for a wide range of applications on our home-
page.

Appendix

Message Codes

All message codes will be displayed with either "InFo"
®
- key {A, 14}.
or "Error".
The following mistakes can be corrected:
InFo
204
206
240
245
252
253
9
Cause
Calculation error
Repeat procedure
No endpiece detec-
Attach the endpiece
tion
properly. If error still
occurs, replace the
endpiece.
Error in data trans-
Repeat process
mission
2nd key pressed
Establish BLUE-
although no BLUE-
TOOTH
®
TOOTH
connection
exists.
Temperature too
Cool down instrument
high
Temperatur too low Warm up instrument