System setup: overview of parameters
4010
Nominal Settings
4011
4012
4013
4014
4020
Nominal Settings 2
4021
4022
4023
4024
4050
Transformer Gen-set
4051
4052
4053
4054
4060
Transformer Bus
4061
4062
4100
Engine Comms.
4101
4110
Date & Time (internal clock)
4110
4110
4120
Counters
4121
4122
4123
4124
4220
Battery Low
4221
4222
4223
4224
4225
4230
Battery High
4231
4232
4233
4234
4235
4240
Language
4241
4250
Battery Low 2
4251
4252
4253
4254
4255
4260
Battery High 2
4261
4262
4263
4264
4265
4290
Mode Relay
4291
4292
4293
4300
Engine Type
4301
4320
Gen-Set Mode
4321
4330
CAN Unit
4331
4350
Tacho Configuration
4351
4352
2954 2100 01
CUSTOMER LEVEL
Frequency
50Hz
Generator Power
13kW
Generator Current
42A
Generator Voltage
230V
CUSTOMER LEVEL
Frequency
50Hz
Generator Power
13kW
Generator Current
42A
Generator Voltage
230V
SERVICE LEVEL
440V
Volt. Prim.
Volt. Sec.
440V
Current Prim.
60A
Current Sec.
5A
SERVICE LEVEL
Volt. Prim.
440V
Volt. Sec.
440V
SERVICE LEVEL
Type
OFF
CUSTOMER LEVEL
Date
dd/mm/yyyy
Time
hh:mm
MASTER LEVEL
Running Time
0
GB Operations
0
MB Operations
0
Reset kWh
OFF
SERVICE LEVEL
Setpoint
9.0V
Delay
3.0s
Output Relay A
R0
Output Relay B
R0
Enable
ON
SERVICE LEVEL
Setpoint
15.0V
Delay
0.5s
Output Relay A
R0
Output Relay B
R0
Enable
ON
CUSTOMER LEVEL
Language
English
SERVICE LEVEL
Setpoint
N/A
Delay
10.0s
Output Relay A
R0
Output Relay B
R0
Enable
OFF
SERVICE LEVEL
Setpoint
N/A
Delay
10.0s
Output Relay A
R0
Output Relay B
R0
Enable
OFF
CUSTOMER LEVEL
Test
R0
Auto
R0
Semi
R0
MASTER LEVEL
Engine Type
Diesel
CUSTOMER LEVEL
Gen-Set Mode
Island
CUSTOMER LEVEL
CAN Unit
bar-celsius
SERVICE LEVEL
Setpoint
500rpm
Teeth
0
4360
Starter
(48.0 ... 62.0)
4361
Start Prepare
(10 ... 20000)
4362
Start ON Time
(0 ... 9000)
4363
Start OFF Time
(100 ... 25000)
4364
Prepare
4370
Start Attempts
(48.0 ... 62.0)
4371
Attempts
(10 ... 20000)
4372
Output Relay A
(0 ... 9000)
4373
Output Relay B
(100 ... 25000)
4380
f/U OK
4381
Delay
(100 ... 25000)
(100 ... 690)
4390
f/U failure
(5 ... 9000)
4391
Delay
(1 / 5)
4392
Output Relay A
4393
Output Relay B
(100 ... 25000)
4400
Stop
(100 ... 690)
4401
Cool Down Time
4402
Extended Stop
4403
Coil Type
(OFF / MDEC / DDEC / EMR / JDEC)
4410
Stop Failure
4411
Delay
( ... )
4412
Output Relay A
( ... )
4413
Output Relay B
4420
Mains V Failure
(0 ... 20000)
4421
Fail Delay
(0 ... 20000)
4422
Mains OK Delay
(0 ... 20000)
4423
Low Voltage
4424
High Voltage
4425
Mains Fail Control
(6.0 ... 36.0)
4430
Mains Hz Failure
(0.0 ... 999.0)
4431
Fail Delay
(R0 ... R3)
4432
Mains OK Delay
(R0 ... R3)
4433
Low Frequency
(ON / OFF)
4430
Mains Hz Failure
4431
Fail Delay
(12.0 ... 36.0)
4432
Mains OK Delay
(0.0 ... 999.0)
4433
Low Frequency
(R0 ... R3)
4434
High Frequency
(R0 ... R3)
(ON / OFF)
4440
MB Control
4441
Function
4442
MB Close Delay
(GB / NL / F / D / E / I / DK / S / N / SF / P)
4450
Alarm Horn
4451
Delay
(6.0 ... 36.0)
(0.0 ... 999.0)
4460
GB Control
(R0 ... R3)
4461
GB Close Delay
(R0 ... R3)
(ON / OFF)
4610
Relay 1
4611
Function
4612
Off Delay
(12.0 ... 36.0)
(0.0 ... 999.0)
4620
Relay 2
(R0 ... R3)
4621
Function
(R0 ... R3)
4622
Off Delay
(ON / OFF)
4630
Relay 3
4631
Function
(R0 ... R3)
4632
Off Delay
(R0 ... R3)
(R0 ... R3)
4710
Start/Stop Cmd. 1
4711
Enable
4712
START/STOP
(Diesel / Gas)
4713
Day(s)
4714
Hour
4715
Minute
(Island / AMF / LTO)
4720
Start/Stop Cmd. 2
4721
Enable
(bar-celsius / psi-farenheit)
4722
START/STOP
4723
Day(s)
4724
Hour
(1 ... 2000)
4725
Minute
(0 ... 500)
Instruction manual
CUSTOMER LEVEL
1.0s
(0.0 ... 600.0)
12.0s
(1.0 ... 30.0)
12.0s
(1.0 ... 99.0)
Normal
(Normal / Extende
SERVICE LEVEL
3
(1 ... 10)
R0
(R0 ... R3)
R0
(R0 ... R3)
SERVICE LEVEL
3.0s
(1.0 ... 99.0)
SERVICE LEVEL
30.0s
(1.0 ... 99.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
SERVICE LEVEL
60.0s
(0.0 ... 990.0)
15.0s
(1.0 ... 99.0)
RUN
(RUN / STOP)
SERVICE LEVEL
20.0s
(10.0 ... 120.0)
R0
(R0 ... R3)
R0
(R0 ... R3)
CUSTOMER LEVEL
1.0s
(1.0 ... 990.0)
60.0s
(10.0 ... 990.0)
75%
(50 ... 100)
120%
(100 ... 150)
Start+Open MB
(Start / Start+Open
CUSTOMER LEVEL
1.0s
(1.0 ... 990.0)
60.0s
(10.0 ... 990.0)
95%
(80 ... 100)
CUSTOMER LEVEL
1.0s
(1.0 ... 990.0)
60.0s
(10.0 ... 990.0)
95%
(80 ... 100)
105%
(100 ... 120)
CUSTOMER LEVEL
Mode Shift OFF
(Mode Shift OFF / Mod
0.5s
(0.0 ... 30.0)
CUSTOMER LEVEL
20.0s
(0.0 ... 990.0)
CUSTOMER LEVEL
1.0s
(0.0 ... 30.0)
SERVICE LEVEL
Alarm
(Limit / Alarm)
0.0s
(0.0 ... 999.9)
SERVICE LEVEL
Alarm
(Limit / Alarm)
0.0s
(0.0 ... 999.9)
SERVICE LEVEL
Alarm
(Limit / Alarm)
0.0s
(0.0 ... 999.9)
CUSTOMER LEVEL
OFF
(ON / OFF)
STOP
(START / STOP)
10
(0 / 1 / 2 / 3 / 4 / 5 / 6 /
10
(0 ... 23)
0
(0 ... 59)
CUSTOMER LEVEL
OFF
(ON / OFF)
STOP
(START / STOP)
10
(0 / 1 / 2 / 3 / 4 / 5 / 6 /
10
(0 ... 23)
0
(0 ... 59)
23