Konlen MOBILE CALL GSM Alarm System User Manual

Konlen MOBILE CALL GSM Alarm System User Manual

Gsm alarm system

Advertisement

Konlen Technology--The proffessional home alarm system provider
MOBILE CALL
GSM Alarm System
Profile
For a better understanding of this product, please read this user
manual thoroughly before using it.
www.konlen.com
USER' MANUAL
S

Advertisement

Table of Contents
loading

Summary of Contents for Konlen MOBILE CALL GSM Alarm System

  • Page 1 Konlen Technology--The proffessional home alarm system provider MOBILE CALL GSM Alarm System USER’ MANUAL Profile For a better understanding of this product, please read this user manual thoroughly before using it. www.konlen.com...
  • Page 2: Table Of Contents

    CONTENTS Function Introduction Alarm Host Diagram Functions Settings Initialization Enter Settings Exit Settings Factory Reset Coding of Remote Controller Delete Remote Controller Coding of Defense Zone Delete Defense Zone Change Password Change Operation Password Change Program Password Clock Setting Timing Settings Timely Arm Timely Disarm Timing Control...
  • Page 3 CONTENTS SMS Number Setting 11-12 Delete SMS Number 12-12 SMS Notification for Arm/Disarm 12-12 Defense Zone Programming 12-13 Home Arm Defense Zone Setting 13-13 Voice Recording 14-14 Siren Setting 14-14 Operation Instructions 15-15 System Status 15-15 Remote Controller Operate 15-15 Out Arm 16-16 Home Arm...
  • Page 4: Function Introduction

    Function Introduction Function Instruction 7 wired and 99 wireless defense zones; LCD screen with time clock display; Voice prompt for all operations; 3 groups of timely arm and disarm; Can store 6 phone numbers: when alarming, system will make alarm call to these numbers automatically;...
  • Page 5: Alarm Host Diagram

    Alarm Host Diagram Alarm Panel front schematic diagram: Alarm Panel back schematic diagram: Wired terminal block: Speaker Siren Alarm Host Diagram...
  • Page 6 Alarm Host Diagram Positive of two-way speaker (red cable) Negative of two-way speaker (black cable) Ground Wired sensor 1: support both NO and NC Ground Wired sensor 2: support both NO and NC Zone 2 Wired sensor 3: support both NO and NC Zone 3 Wired sensor 4: support both NO and NC Zone 4...
  • Page 7: Lcd Display

    Alarm Host Diagram LCD display: Functions Settings 1. Initialization Please insert SIM card and plug in power adaptor, and then power on the system, all the LED lights will be on for 2 seconds and you will hear a long beep;...
  • Page 8: Exit Settings

    Functions Settings Note: In setting status, press can delete the numbers input. The system default password is [8888]. Operating method: [ XXXX ] X indicates the new 4-digit password. LCD display: 3. Exit Settings Press [ ] and [#] buttons, the main unit emits a long beep and exits settings. The [ SET ] indicator goes out and the system returns to disarm state.
  • Page 9: Delete Remote Controller

    Functions Settings You can add maximum 8 remote controllers. LCD display: 6. Delete Remote Controller The remote controller can ‘t control the main unit after it ‘s deleted. In setup state, use keypad to input [21 ], then input the remote controller number [1-8], and then press [ # ] to confirm.
  • Page 10: Delete Defense Zone

    Functions Settings 8. Delete Defense Zone The wireless detector can’ control the main unit after it’ deleted. In setup state, use keypad to input [24], then input the defense zone number you want to delete [ 01~99 ], and then input [#] to confirm. The main unit emits a long beep and the defense zone indicator flickers once.
  • Page 11: Clock Setting

    Functions Settings Operating method: [31] [ XXXX ] XXXX indicates: the new 4-digit password For example: change the system password to 2846 Operating method: [31] [2846] LCD display: Note: the operation password and the programming password can not be set as the same number. 10.
  • Page 12: Timing Settings

    Functions Settings 11. Timing Settings 1 ). Timely Arm In setup status, use keypad to input [33~35], then input the hour [AA] and minute [BB] of the time you want to set to arm, and finally input [#] to confirm. You will hear a long beep and a voice prompt “setting completed”.
  • Page 13: Timing Control

    Functions Settings 3). Timing Control In setup status, use keypad to input [39], then input the number indicating turning on timely arm/ disarm [1/0], and then input [#] to confirm. You will hear a long beep and a voice prompt “setting completed”. The factory default is off.
  • Page 14: Delete Phone Number

    Functions Settings XX indicates: the 1- 6 alarming user number [51] ~ [56] YY….YY indicates: voice alarm-receiving phone number For example: set 13811111111 as the first voice call number Operating method: [51] [13811111111] [#] LCD display: 13. Delete Phone Number In setup state, input [51] ~ [56], and then press [#] to confirm, the main unit will make a long beep and the [Signal] indicator will flicker once and you will hear “delete completed”, which indicate the alarming user...
  • Page 15: Delete Sms Number

    Functions Settings For example: setup 13822222222 as the first SMS receiving number Operating method: [57] [138222222] [#] 15. Delete SMS Receiving Number In setup state, use keypad to input [57] ~ [59], a nd then press [#] button to confirm. The main unit will make a beep, the [ Signal ] indicator will flicker once and you will hear “delete completed”, which indicate SMS number is deleted successfully.
  • Page 16: Home Arm Defense Zone Setting

    Functions Settings AA: defense zone number [01~99] means zone 1 to zone 99; B: defense zone type [1]: real-time defense zone [2]: 40 seconds delay defense zone [3]: 24 hours defense zone [4]: bypass defense zone C: defense zone location [1] SOS Alarm [2] Fire Alarm [3] Gas Leak Alarm...
  • Page 17: Voice Recording

    Functions Settings 18. Voice Recording In setup state, use keypad to input [701], and then press [#] to confirm. The main unit will emit a beep and the [ ] indicator is on, and after 10 seconds countdown, recording starts: record at 30cm away from the main unit with moderate tone;...
  • Page 18: Operation Instructions

    Functions Settings Operation Instructions 1. System status. There are 4 status as following Arm: defense zone 1~99 will alarm when detectors are triggered Home Arm: in arm status, the defense zone which is set as [Home Arm] will alarm when detectors are triggered. Disarm: defense zone 1~99 will not alarm when detector triggered (except 24 hours defense zone) System setup status: In this status, all defense zones will not alarm...
  • Page 19: Out Arm

    Functions Settings 4. Out Arm It means to guard all around your house while everyone is going out; all the detectors of the host are always working; when the detector is triggered by detecting source (anti-theft, fire prevention, gas leak, etc.), the alarm system will sound the alarm.
  • Page 20: Answer Alarm Call

    Functions Settings After the setting, the host makes "Di" Di" sound, ARM LED is off and you will receive a SMS: System disarmed. Note: If you send arm or disarm SMS by the mobile phone number stored in the system before (refer to “SMS Receiving Number Setting), you will receive two arm/disarm SMS.
  • Page 21: Emergency Help

    Functions Settings Press [1]: arm, if finished successfully, you will hear a voice prompt “System armed”. Press [2]: disarm, if finished successfully, you will hear a voice prompt “System disarmed”. Press [3]: monitoring for 30 seconds, to continue monitoring, press [3] again to monitor for another 30 seconds.
  • Page 22: Gsm Signal Checking

    Functions Settings For example: the 51st defense zone; the 7th alarming; alarming time: 12:10, August 1st, 2008. LCD display for one second, and then display the alarming time: You can also check the alarm records by SMS ( Max: Latest 9 records). SMS Check Command: Remote Control Password (Default: 1234) + [3] Reply SMS: Eg: Alarm record:...
  • Page 23: Technical Parameters

    Technical Parameters Technical Parameters List 1: Input Voltage DC12V/1A Standby Current <55mA Alarming Current <450mA Wireless Frequency GSM Frequency 900/ 1800/ 1900MHz Back-up Battery NI-HI AAA*6 DC7.2V Siren Volume 110dB List 2: Alarm Information Siren Defense Zone Home Arm Type Zone 1 effective invalid...
  • Page 24: Components List

    Components list Components list Main panel Remote controller 2pcs Siren PIR sensor Door sensor Power adapter User manual Care and Maintenance The alarm system has excellent design and uses advanced technologies. It shall be used with care. The following suggestions are required to maintain your obligations under the warranty terms, and for prolonging the service life of the system.
  • Page 25 Care and Maintenance Check the main unit every three months: 1. Whether it can arm/disarm normally; 2. Whether it can dial the number for alarm normally; 3. Whether it can receive wireless detectors’signal normally; 4. Whether the back - up battery can work normally. Check the wireless detectors once a month: 1.
  • Page 26 Care and Maintenance Do not drop this product on the ground or on hard objects, as it may lead to massive impact to cause faults and damages. Without approval and consent of relevant authorities, please do not set “110”, “119” or the alarm phone number of police station for this main unit.
  • Page 27 Care and Maintenance Optional sensors/detectors are packed separately. They include remote controller, outdoor siren, transmitter, wireless PIR, wireless gap sensor, wireless gas detector, wireless smoke detector, panic button, baluster, etc. You can choose according to your specific requirements. Care and Maintenance...
  • Page 28 MOBILE CALL GSM Alarm System 2011.12.V2.0...

This manual is also suitable for:

Mobile call