Restoring Default Codes; Restoring Default Programming; Glossary Of Terms - C&K systems S802 Installation Manual

Security control panel
Table of Contents

Advertisement

FACTORY PROGRAMMING DEFAULTS 9-9
FACTORY
DEFAULTS
Factory defaults have been split into two sections, programming and codes.
RESTORE
DEFAULT
To return to factory programming defaults first enter Engineering Mode then
PROGRAMMING
proceed as follows:-
1)
2)
RESTORE
DEFAULT
CODES
If at any stage you want to default the customer codes, follow this procedure while
in engineering mode.
1)
"Memory
2)
GLOSSARY OF
TERMS
3)
FULL SET
This is a setting method normally used when leaving the premises. Full system armed.
NIGHT SET
This is a setting method normally used when going to bed
HOME SET
This is a setting method normally used for high security protection whilst still inside the
premises. For example an antiques cabinet etc.
ALARM
This is a zone that will trigger the panel when activated, providing the panel is set.
WALK THROUGH
This zone will be disabled during an entry period.
ISOLATE IN NIGHT SET
This simply means the zone will be disabled when the panel is NIGHT SET. For example
downstairs may be armed but upstairs may be disabled.
Enter 9-9
Any extension sounders will give a rapid pipping sound. The internal
keypad sounder will emit a steady tone.
Enter the engineer code.
If entered correctly an accept tone will sound and the factory programming
defaults will be restored. If any error is made an error tone will sound and
the programming will not be altered. The user and engineer codes have
not changed.
Place the small link supplied with the spare fuses, on the memory link.
Then remove the mains and battery power.
The link is positioned left of the LEDS near the top of the pcb and is labelled
Default".(at which point zone 1 light will illuminate)
Wait a few seconds then re-connect the battery and then the mains and
then refer to page 6 regarding initial power up.
The speaker will omit the accept tone and the factory user code defaults
will be restored.
Remove the link. ( at which point zone 1 light will go out ).