C&K systems S802 Installation Manual page 13

Security control panel
Table of Contents

Advertisement

NIGHT SET ENTRY
This means when the panel is NIGHT SET the zone, when activated, will start the entry
timer but if the panel is FULL SET then this zone will simply act as an ALARM zone
ENTRY CIRCUIT
This will start the entry timer when activated providing the panel is set.
FIRE (for use with smoke detectors etc.)
This is a zone that when activated will emit an ascending sound from any internal
speakers. If the panel is set, external sirens and strobes will also sound but in an unset
state the external sounders will pulse every two seconds.
TAMPER
This is a loop that should run through every device on your system. If broken, it will trigger
the internal speakers. If the panel is set, external sounders and strobes will also trigger.
The tamper LED is shown on the keypad as TPR
CHIME
Chime is similar to a doorbell. This can be used to alert a user to a certain zone being
triggered during the day.
DOOR SENSE SETTING
This allows you to have a variable FULL SET EXIT TIME. You can program the EXIT time
to maximum and when you full set the system, the exit time will drop to 8 seconds as soon
as the EXIT door has closed thus avoiding the preset exit time.
FULL SET KEYSWITCH
This allows the panel to be set, unset and reset via zone 8. This is performed by using a 2
position keyswitch (make / break) across the zone. To set, open the zone. To unset, close
the zone. To Reset you must open and close the zone after an alarm condition.
THE * KEY (STAR)
This is commonly used as an ACCEPT or STORE button
THE # KEY (HASH)
This is commonly used as RESET, CANCEL or EXIT
THE ACCEPT TONE
This is heard when an action is accepted. The sound made is "diddly dee"
THE ERROR TONE
This is heard when an action is not accepted. The sound made is "dee dah"
SERIES AND PARALLEL
LATCHING DETECTORS
These detectors, when triggered during a set period, latch on to aid the process of alarm
event origin checking. These detectors are only normally used if many detectors are to be
used on a single zone but are to cover a large area of space.
Series
Parallel
12
GLOSSARY
OF TERMS