MOUNTING A REMOTE KEYPAD
1)
Locate the position for your keypad then mark the holes for mounting.
2)
Make sure the cable is run through the backbox.
3)
Screw the backbox in the agreed position making sure it is not twisted.
WIRING A REMOTE KEYPAD
1)
All remote keypads require 6 core cable for their connection.
2)
Connect the cable into the terminals shown below in diagram C making
sure each wire goes to a like named terminal in the panel. C goes to C, D
goes to D, + goes to + and - goes to -. The tamper wires are wired in series
with your existing tamper loop. Refer to series & parallel examples in
glossary for details.
Individual keypads do not need to be identified to the system. If more than one
remote keypad is in use it can be either wired back to the control panel or daisy-
chained from another keypad. All connections are in parallel with the exception of
the tamper circuit which MUST be wired in series.(see glossary of terms for series
and parallel examples).
INITIAL POWER UP
NOTE The lid should remain off the main control panel so that engineer mode may
be used. Alternatively, entering 7890 # can also be used to enter engineer mode. If
the engineers code is entered and the panel is then left, it will set.
Switch the mains supply on, the internal sounder will start.
1)
This denotes a tamper alarm.
Enter 1 2 3 4 followed by the # (hash) button - this will silence the sounder
2)
and the TAMPER LED will flash. Fit the link onto LINK 1
This has now acknowledged and cancelled the alarm. By inserting LINK 1, you
have disabled the onboard tamper.
3)
Connect your battery and walk test the control panel.
This will make sure all the zones are clear.
4)
Power Down and complete the wiring of the control panel. Remove LINK 1
NEVER wire the control panel live. You have also re-enabled the onboard tamper
loop.
5)
Power back up, cancel the alarm and enter engineering mode by entering
7, 8, 9, 0. Close Lid when all the wiring is completed
The panel is now ready for programming.
** DIAGRAM C **

POWERING UP

6
MOUNTING
REMOTE
KEYPADS
WIRING
REMOTE
KEYPADS
KEYPAD
DIAGRAM
INITIAL
POWER UP