5. Schedule Timer
Power Outages
If the air conditioner is running when power is lost, the air conditioner remains OFF when power is restored. Also, if remote con-
troller operation was disabled when power was lost, it is enabled for a few minutes when power is restored.
Programmed operations scheduled for times that come after power is restored run as usual.
Program settings are retained in the non-volatile memory of the schedule timer, therefore they are not cleared in the event of
a power outage. Also, the present time and today's day of the week are retained for a maximum of 100 hours by the internal
battery.
Schedule timer settings (Example)
Operation when power is not lost
1
Air conditioner
operation
2
Remote controller
operation
3
Operation when power is lost at 15:00 and subsequently restored
4
Air conditioner
5
operation
Remote controller
operation
6
7
8
8:00
Stopped
Running
*1
Enabled
*1 Whether remote controller operation is enabled or disabled depends on the setting of the
previous day.
8:00
Stopped
Running
Enabled
*1
*1 Whether remote controller operation is enabled or disabled depends on the setting of the
previous day.
*2 Remote controller operation is enabled for a few minutes after power is restored.
Control of W-2WAY ECO-i SYSTEM
12:00
13:00
Stopped
Running
Disabled
Power lost here.
15:00
12:00
13:00
Stopped
Running
Disabled
3-80
17:00
18:00
20:00
Stopped
Stopped
Running
Enabled
Disabled
17:00
18:00
20:00
Stopped
Running
Stopped
Disabled
Enabled
Disabled
*2