Sanyo SPW-C1155DXHN8 Technical Data & Service Manual page 173

2-way eco-i multi system
Hide thumbs Also See for SPW-C1155DXHN8:
Table of Contents

Advertisement

2. Indoor Unit
Unit Specifications
MODEL NAME
MODEL No.
POWER SOURCE
PERFORMANCE
Total
Capacity
Expansion Coil
Enthalpy exchange
Total heat
efficiency
exchanger
Temperature exchange
Air circulation (High at 230 V)
Moisture removal (High)
Air Charge
External Static
Pressure
Air Discharge
ELECTRICAL RATINGS
Voltage rating
Available voltage range
Running amperes
Power input
Power factor
Starting amperes
FEATURES
Heat exchanger
Controls
Fan speeds
Air Charge
Air filter
Air Discharge
Refrigerant control
Operation sound
Refrigerant tubing connections
Liquid tube
Refrigerant tube
diameter
Gas tube
Drain connection
Drain pump
Duct connection port
Timer Remote Controller
High performance filter
Humidifier
Supplied accessories
DIMENSIONS & WEIGHT
Height
Unit dimensions
Width
Depth
Net weight
Rated conditions
• (Low*): When the supplied external static pressure line switching connector is connected.
• The numerical value within the parenthesis of fresh air conditioning load throughput is value of the heat recovery amount due to total heat
exchange.
• As for the Direct-Expansion Coil efficiency, when it is run under the test conditions stated below
Cooling: Direct-Expansion Coil port temperature 27 °C DB and 19 °C WB (discharge air), Outdoor air inlet temperature 35 °C DB and 24 °C
WB (charge air).
Heating: Direct-Expansion Coil port temperature 20 °C DB (discharge air), Outdoor air inlet temperature 7 °C DB and 6 °C WB (charge air)
• Efficiency of the total heat exchanger depends on the following conditions.
Summer: Indoor temperature 27 °C DB & 20 °C WB (discharge air), Outdoor temperature 35 °C & DB 29 °C WB (charge air).
Winter: Indoor temperature 20 °C DB & 14 °C WB (discharge air), Outdoor temperature 5 °C & DB 2 °C WB (charge air).
• The operation sound is measured when the unit is connected to the duct and operated in the anechoic room, associated with the value
measurement directly 1.5m from under the unit.
Once true installation effects taken into account, the actual levels will exceed the indicated values due to reflections off adjacent surfaces and
peripheral noise.
• The changes of H/L of external static pressure depend on the plug equipped connector. However, it will not affect the remote control indication
and will display the HIGH mark.
• This unit has no solvent resistance. Please pay attention to the installation site.
W-2WAY ECO-i SYSTEM Unit Specifications
Heat Recovery with Direct-expansion Coil
220 - 230 - 240 V / single-phase / 50 Hz
Cooling
kW
7.46
kW
4.5
Summer(%)
Winter(%)
%
3
M
/ h
Liters / h
3.0
Pa
Pa
V
220
230
V
198 - 264
A
3.4
3.2
kW
0.737
0.737
%
99
99
A
Direct-Expansion Coil: Plate finned tube
Total heat exchanger: Static conversion
dB - A
mm (in.)
mm (in.)
mm
Optional (natural evaporating type)
External static pressure line switching connector,
Insulation, Clamper, Installation and Operating Manual.
mm
mm
mm
kg
4-27
SPW-GU075XH
Heating
8.79
58
66
73
750
221
264
240
220
198 - 264
3.1
3.4
0.737
0.737
0.737
99
99
9.2
Microprocessor
High, (Low*)
Long-life filter (Washable)
Long-life filter (Washable)
Electronic Expansion Valve
51
Flare type
6.35 (1/4)
12.7 (1/2)
25A (Connection port R1 screw)
ø 250 × 4
Optional (RCS-TM80BG)
Optional (65% colorimetric)
450
1,903
1,120
180
5.0
230
240
3.2
3.1
0.737
99
99
1
2
3
4
5
6
7
8