use the 4" piece of gear rack included in the small
parts kit to time the gear rack.
A short piece of gear rack is
provided in the small parts
kit to properly space the gear
rack splices.
There may be a gap between two pieces of gear
rack when spacing the splice. This is acceptable
as long as the distance between the teeth is
consistent. This can be verified by matching the 4"
piece of gear rack to the splice.
area able to be omitted in
rack splice
load the loose 38" piece of gear rack from the top, and
slide up to meet the other gear rack. Time and tighten
gear rack.
Note: There is not a top or bottom end of the gear rack.
Tighten the pieces of gear rack down in place.
Turn the track assembly right side up on the stairway.
6
Do not tighten gear rack until the
proper spacing has been achieved.
d. InSTall lower end Cap
slide one T-bolt on the gear rack side of the track.
STEP MAY NOT APPLY TO YOU: Slide 1 T-bolt on each
T-slot ONLY in installations where track does not touch
the floor of the bottom landing, such as when track stops
on first step. If the track will be resting on the floor, skip
this step and proceed to step 4.
slide the end cap onto the lower end of the track,
inserting the dove tail into the groove on the top of the
track.
Note: If you skipped step 3 because of the type of
installation you are performing, skip step 6 as well.
Fasten the end cap to the track with the T-bolts and
nuts provided.