Preliminary Checks; Installation Site Requirements; Tools Required; Shipment - ThyssenKrupp Access Citia Installation And Service Manual

Alternating current systems stair lift
Table of Contents

Advertisement

I.

prelIMInary CheCkS

a. InSTallaTIon SITe requIreMenTS
dedicated* 115Vac, 60 hz, 3-wire grounded outlet
within 13' of the top or bottom of the staircase.
stair angle between 25° and 45°.
Indoor residential installation.
* nec requirement
b. ToolS requIred
set of phillips head screwdrivers
Tape measure
3/8" reversible drill with 3/8" hex socket and a 6"
extension
3/16" allen wrenches
13mm socket
Flat metal file
Torque wrench rated to at least 18ft.lbs. of torque
portable band saw or hack saw (for cutting track)
safety items: steel toe shoes, safety glasses, gloves,
etc.
Torpedo level
combination square
Tools for removing hand rail if it interferes with the
travel of the stair lift
stubby 13mm open end wrench
1/2" combination wrench
4mm allen wrench
1/8" allen wrench
Wire cutters
knife
C. ShIpMenT
Verify all components are included with the shipment:
Seat Box:
• Seat assembly
Chassis Box:
• Chassis assembly
• (1) Power supply
• (2) Remote controls
• (2) 9 volt batteries for remote controls
• Unit small parts
- (4) chassis wheels
- (1) Tube of lubricant
- (1) set of Velcro
®
- (1) Fuse
Track Box:
• (2) 8' pieces of track with gear rack and splice bars
• (1) 38" long piece of gear rack (loose)
• (6) Track brackets
• (2) Track end caps
• Small parts kit:
- (1) 4" long piece of gear rack for splice timing
- Fasteners for track brackets and track end caps
- (12) Track bracket covers
- (2) splice bars
- (4) set screws