Zero Clearance (Metal) Fireplace Installation; Preparation For Installation - Travis Industries X-96 Owner's Manual

Table of Contents

Advertisement

PREPARATION FOR INSTALLATION -

ZERO CLEARANCE (METAL) FIREPLACE
READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW APPLIANCE. FAILURE TO
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
PREPARATION:
1. Remove all tape and packaging.
2. Remove the wood shipping frame from around and under the appliance.
3. Check that no parts have become loose and the appliance has not been damaged during shipping.
4. Remove the hardware pack from the appliance.
5. READ THE OWNER'S MANUAL BEFORE PROCEEDING.
*
Appliance should be located such that no doors, drapes, furniture or other combustibles can be
placed close or swing closer than the minimum 36" clearance.
*
The appliance must be installed in a level, secure position.
REQUIRED FLOOR PROTECTION:
NOTE: Minimum hearth extension of 36 1/4"" width by 18" depth from fireplace insert door opening is
required.
CHIMNEY LENGTH
Vertical
OPTIONS
Your fireplace insert comes completely assembled. Options available for your fireplace insert are listed
below. Installation instructions for these options are in the section "INSERT OPTIONAL EQUIPMENT".
1. Surround Panels - 8", 10", and 12" Sizes (Includes Insulation)
2. Surround Panel Brass Trim (Included with Surround Panels)
3. Bay Kit
4. Blower, Front
5. Flue Adapter (6")
SAFETY
For your safety, examine the fireplace and chimney prior to installation of the appliance to determine that
they are free from cracks, creosote deposits, blockages, or other signs of deterioration. If evidence of
deterioration is noted, the insert should not be installed until after repairs have been made.
Your Lopi X-96 is listed for installation into the following brands of zero clearance (metal) fireplaces.
¥ Marco
¥ Preway
When lifting the appliance, you may choose to remove the interior components to make it lighter. Refer to
the section "REPLACEMENT PARTS AND REMOVAL INSTRUCTIONS" for the proper sequence of
removal and replacement of internal components.
Maximum
33 Feet
¥ Majestic
¥ Tempco
Page 24
Minimum
15 Feet
¥ Heatilator
¥ Superior