FIELD
TITLE and DATA ENTRIES
*178
RF Supervision / RF Jam Option
0 = RF supervision and RF jam detection
reporting
1 = Report RF supervision failure as tamper
alarm when armed
2 = Report RF Jam as tamper alarm when
armed
3 = Report RF Jam and RF supervision
failure as tamper alarm when armed**
Zone Bypass Limit
*180
0 = unlimited zone bypasses in each partition
1-7 = number of zone bypasses allowed in
each partition
AC and Clock Display Options
*181
0-15 = desired options based on chart at
right.
*182
Summer Time Switchover Day
0 = switch on Sunday morning
1= switch on Saturday morning
2 = switch on Friday morning
*183
Date/Time Format
0 = 12-hour time/MMDDYY date
1 = 12-hour time/DDMMYY date
2 = 24-hour time/MMDDYY date
3 = 24-hour time/DDMMYY date
EXPLANATION
Select desired option. See field *22 for related options.
Entry 0: RF jam conditions report as Trouble zone 90 (Contact ID
code 344, RF Rcvr Jam Detect) plus a zone trouble report for
each RF zone in the system (CID code 383, Trouble Sensor
Tamper) when the system is armed or disarmed. Keypads
display Tamper zz (zz = zones) and Tamper 90 (fixed-word)
or RECEIVER JAM (alpha).
RF supervision failures report as zone troubles (CID code
381, RF Sensor Super.) when the system is armed or
disarmed. Keypads display CHECK zz (zz = zone).
Entry 1: Same as entry 0 except RF supervision failures report as
zone alarms (CID code 144, Alarm Sensor Tamper) when
the system is armed; keypads display ALARM zz.
Entry 2: Same as entry 0 except RF jam conditions report as zone
alarms (Contact ID code 144, Alarm Sensor Tamper) when
the system is armed; keypads display ALARM zz.
Entry 3: Same as entry 0 when disarmed, but when the system is
armed, both RF jam conditions and RF supervision failures
report as zones alarms (Contact ID code 144, Alarm Sensor
Tamper)
NOTES: RF Jam must be enabled in field *22 in order for any RF
reporting to be enabled in this field.
Alarm restore reports must be enabled (field *70) in order for RF
Supervision/RF Jam alarm restores to be reported.
Trouble reports and trouble restore reports must be enabled (fields
*60, *71) in order for RF supervision/RF jam trouble conditions and
restores to be reported.
Select the maximum number of zones that can be bypassed.
Each partition individually uses this entry.
Use the following table to select the desired options for real-time clock
synchronization (50Hz, 60Hz, Crystal), AC loss display (independent
of AC loss report enabled in *62), and clock display (time displayed on
bottom line of alpha keypads).
X10 NOTE: "X10" (powerline carrier devices) use the selected AC
frequency to communicate with the control.
Entry
AC Freq.
Crystal for AC Loss disp Clock disp
0
60Hz
clock backup
1
50Hz
clock backup
2
60Hz
3
50Hz
4
60Hz
clock backup
5
50Hz
clock backup
6
60Hz
7
50Hz
8
60Hz
clock backup
9
50Hz
clock backup
#+10
60Hz
#+11
50Hz
#+12
60Hz
clock backup
#+13
50Hz
clock backup
#+14
60Hz
#+15
50Hz
Select the appropriate summer time switchover day.
Select the desired time and date format.
no
no
no
no
clock
no
no
clock
no
no
yes
no
yes
no
clock
yes
no
clock
yes
no
no
yes
no
yes
clock
no
yes
clock
no
yes
yes
yes
yes
yes
clock
yes
yes
clock
yes
yes
4-11