Installation Instructions
FIELD
TITLE and DATA ENTRIES
Part. 1 Secondary Subs. Acct. No.
*44
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 2 Primary Subs. Acct. No.
*45
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 2 Secondary Subs. Acct. No.
*46
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Phone System Select
*47
If Central Station Receiver is not on satellite
link: 0 = Decadic Pulse Dial;
1 = Multifrequency Tone Dial
If Central Station Receiver is on satellite link:
2 = Decadic Pulse Dial;
3 = Multifrequency Tone Dial
Report Format
*48
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = CID* using 10-digit account number
6 = 4+2 ADEMCO EXPRESS
7 = CID* using 4-digit account number
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
10 = ROBOFON 8 (6-digit account number)
11 = ROBOFON Contact ID
Split/Dual Reporting
*49
0 = disable (standard/backup report only).
1 - 5 (see table to right)
Burglary Dialer Delay
*50
0 = no dial delay (UL: must be "0")
1 = 15 seconds
2 = 30 seconds
3 = 45 seconds
Part. 3 Primary Subs. Acct. No.
*51
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 3 Secondary Subs. Acct. No.
*52
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
SESCOA/Radionics Select
*53
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
Dynamic Signaling Delay
*54
0 = disabled (both signals sent)
1–15 = entry times a 15-second delay.
e.g., 1 = 15 seconds, 2 = 30 seconds, etc.
4-4
EXPLANATION
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press ∗44∗.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press ∗45∗.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press ∗46∗.
Select the type of telephone service.
Select report format for primary and secondary phone numbers.
(Primary/Secondary)
* ADEMCO Contact ID format
NOTE: To enable the audio "beeps" format (Follow-Me feature), refer
to the System Features section later in this manual, and the User
Guide.
1 = alarms, restore, cancel
2 = all except open/close, test
3 = alarms, restore, cancel
4 = all except open/close, test
5 = all
Provides delay of "BURGLARY ALARM" report to the central station,
which allows time for the subscriber to avoid a false alarm
transmission. This delay does not apply to zone type 24 alarms (silent
burglary) or to 24-hour zone types 6, 7, and 8 (silent panic, audible
alarm, auxiliary alarm), which are always sent as soon as they occur.
Enter up to 10 digits, depending on the report format selected in field
*48.
Enter up to 10 digits, depending on the report format selected in field
*48.
Select SESCOA or Radionics format.
Select 0 for all other formats.
Intended for use with ECP Contact ID Output reporting via ACM.
This field lets you select the time the panel should wait for
acknowledgment from the first reporting destination (see ∗55) before
it attempts to send a message to the second destination. Delays can
be selected from 0 to 225 seconds, in 15-second increments. This delay
is per message. If "0" is entered in this field, the control panel will
send redundant reports to both Primary Dialer and ECP output.
To Primary No.
To Secondary No.
others
open/close, test
all
all
all