Lennox G61MPV Engineering Data page 33

Dave lennox signature collection multi−position − two−stage heat − variable speed blower gas furnaces
Hide thumbs Also See for G61MPV:

Advertisement

BLOWER DATA
G61MPV−60D−135 BLOWER PERFORMANCE (less filter)
Single Side Return Air − Air volumes in bold require field fabricated transition to accommodate 20 x 25 x 1 in. cleanable air filter in
order to maintain proper air velocity across the filter.
0 through 0.80 in. w.g. External Static Pressure Range
ADJUST"
ADJUST"
S
Switch
tc
P
Positions
iti
+
1
NORM
ADJUST"
Switch
Switch
Positions
+
1
NORM
1
Factory default jumper setting.
N/A − First and second stage HEAT positions shown cannot be used on this model.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm.
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 470 cfm.
G61MPV−60D−135 BLOWER MOTOR WATTS
J
Jumper Speed
S
d
Positions
Positions
0
0.1
+" (Plus) SETTING ( Adjust" Jumper at +" Setting)
HEAT"
Tap 1 150
175
Speed
S
d
Tap 2 205
235
Tap 3 315
345
Tap 4 430
460
COOL"
Tap 1 90
110
S
Speed
d
Tap 2 105
130
Tap 3 150
175
Tap 4 195
230
NORM" (Normal) SETTING ( Adjust" Jumper at NORM" Setting)
HEAT"
Tap 1 120
140
Speed
Speed
Tap 2 155
185
Tap 3 235
265
Tap 4 320
355
COOL"
Tap 1 70
90
Speed
Speed
Tap 2 80
100
Tap 3 120
140
Tap 4 145
175
−" (Minus) SETTING ( Adjust" Jumper at −" Setting)
HEAT"
Tap 1 N/A
N/A
Speed
Speed
Tap 2 125
150
Tap 3 155
185
Tap 4 205
240
COOL"
Tap 1 60
75
Speed
Speed
Tap 2 60
75
Tap 3 90
110
Tap 4 120
140
Second Stage HEAT" Speed − cfm
1
1
2
1470
1650
1845
1325
1495
1680
N/A
1335
1505
First Stage HEAT" Speed − cfm
1
1
2
1335
1510
1695
1210
1370
1540
N/A
1225
1375
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
0.2
0.3
0.4
0.5
210
240
270
300
330
275
310
355
395
430
385
420
460
495
535
495
530
575
620
665
140
170
195
220
240
165
195
215
235
260
205
235
270
300
330
270
305
340
375
410
170
200
225
255
280
220
255
295
335
365
300
330
370
405
440
390
430
465
505
540
115
135
165
190
210
130
160
185
210
230
170
195
225
255
280
215
250
280
315
345
N/A
N/A
N/A
N/A
N/A
175
195
230
265
290
215
250
285
320
355
285
325
355
385
420
95
115
135
150
175
100
125
150
175
195
140
165
190
215
235
170
195
225
255
275
Speed Switch Positions
3
4
2040
1585
1865
1430
1670
1275
3
4
1870
1105
1710
990
1515
890
0.6
0.7
0.8
0
0.1
360
390
180
215
465
500
275
315
570
610
415
450
705
750
535
585
265
290
230
265
290
315
285
330
360
385
425
465
445
480
605
650
305
330
150
175
395
425
205
240
470
500
290
330
575
610
395
440
230
245
170
200
255
275
245
270
305
330
350
385
375
410
455
500
N/A
N/A
N/A
N/A
310
335
150
175
385
420
205
235
460
495
290
325
195
220
140
160
215
235
145
180
255
270
230
265
300
325
330
365
Second Stage COOL" Speed − cfm
1
2
3
1705
1905
1545
1765
1370
1565
First Stage COOL" Speed − cfm
1
2
3
1180
1330
1075
1210
950
1085
Second Stage
0.2
0.3
0.4
0.5
255
295
330
365
360
400
435
470
490
525
565
600
640
695
730
765
310
355
390
425
380
430
455
485
515
560
605
645
695
740
800
855
210
240
270
300
275
315
350
385
380
430
460
485
485
530
575
620
235
265
305
345
305
335
370
410
420
455
495
530
555
605
645
680
N/A
N/A
N/A
N/A
210
240
255
290
270
305
345
380
360
400
440
480
185
205
240
280
215
250
290
325
305
345
380
420
405
445
485
525
1
4
2130
1975
1755
1
4
1500
1355
1210
0.6
0.7
0.8
400
430
465
510
550
585
640
675
715
810
860
905
460
490
525
525
565
605
685
730
770
900
945
985
335
365
400
422
460
495
515
545
575
660
700
740
380
420
455
440
470
505
570
610
645
725
770
810
N/A
N/A
N/A
330
370
405
420
455
490
515
545
580
305
335
360
355
385
420
450
480
510
560
595
635