OPTIONAL ACCESSORY DIMENSIONS − INCHES (MM)
WALL ASSEMBLY TERMINATION KIT − RING KIT
15F74 − 2 inch (51 mm)
See Installation Instructions for specific usage.
DIRECT VENT APPLICATION
NOTE − 12 in. (305 mm) minimum height above
8 in. (203 mm)
minimum
12
(305)
INTAKE
AIR
5 (127)
5-1/2
(140)
É É É É É É É É É É É É É
É É É É É É É É É É É É É
G61MPV / Page 14
average snow accumulation.
12 in. (305 mm) maximum
without support
6 in. (152 mm)
maximum
DIRECT VENT APPLICATIONS
WALL TERMINATION KITS (CLOSE-COUPLE)
22G44 − 2 inch (51 mm)
44J40 − 3 inch (76 mm)
See Installation Instructions for specific usage.
INSULATION
(Not Furnished)
EXHAUST
AIR
GRADE
NON−DIRECT VENT APPLICATION
NOTE
EXHAUST PIPE SHOWN
Kit Contains Enough Parts For Two Installations
NOTE
EXHAUST
2
(51)
12
(305)
É É É É É É É É É É É É É É É
É É É É É É É É É É É É É É É
12 in. (305 mm) minimum height above
average snow accumulation.
12 in. (305 mm) maximum
without support
If Intake and Exhaust Pipe is less than
12 in. (305 mm) above snow accumula-
tion or other obstructions, field fabri-
cated piping must be installed.
AIR
INTAKE
AIR
12 (305)
Minimum
ABOVE GRADE
12
(305)
GRADE