Download Print this page

Lennox G61MPV Engineering Data page 29

Dave lennox signature collection multi−position − two−stage heat − variable speed blower gas furnaces
Hide thumbs Also See for G61MPV:

Advertisement

BLOWER DATA
G61MPV−60C−111 BLOWER PERFORMANCE (less filter)
Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side.
0 through 1.00 in. w.g. External Static Pressure Range
ADJUST"
ADJUST"
Switch
S
tc
P
Positions
iti
+
1
NORM
ADJUST"
Switch
Switch
Positions
+
1
NORM
1
Factory default jumper setting.
N/A − First and second stage HEAT positions shown cannot be used on this model.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm.
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 458 cfm.
G61MPV−60C−111 BLOWER MOTOR WATTS
J
S
d
Jumper Speed
Positions
Positions
0
0.1
+" (Plus) SETTING ( Adjust" Jumper at +" Setting)
HEAT"
Tap 1 210
235
S
Speed
d
Tap 2 265
305
Tap 3 425
460
Tap 4 540
580
COOL"
Tap 1 120
140
S
Speed
d
Tap 2 145
165
Tap 3 190
220
Tap 4 275
305
NORM" (Normal) SETTING ( Adjust" Jumper at NORM" Setting)
HEAT"
Tap 1 160
185
Speed
Speed
Tap 2 205
235
Tap 3 325
350
Tap 4 410
445
COOL"
Tap 1 90
110
Speed
Speed
Tap 2 105
130
Tap 3 145
165
Tap 4 190
220
−" (Minus) SETTING ( Adjust" Jumper at −" Setting)
HEAT"
Tap 1 120
140
Speed
Speed
Tap 2 155
180
Tap 3 240
265
Tap 4 305
335
COOL"
Tap 1 75
90
Speed
Speed
Tap 2 85
105
Tap 3 115
135
Tap 4 155
175
Second Stage HEAT" Speed − cfm
1
1
2
1585
1810
1430
1635
1265
1440
First Stage HEAT" Speed − cfm
1
1
2
1450
1650
1295
1475
1165
1330
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
0.2
0.3
0.4
0.5
0.6
270
300
335
365
395
345
385
425
465
505
490
525
560
590
615
625
665
710
745
780
165
190
215
235
260
190
215
235
260
290
250
285
320
345
375
340
375
410
440
470
215
245
270
295
320
275
310
350
380
410
380
410
440
470
500
480
520
555
595
630
135
160
185
200
220
155
180
205
230
250
195
220
250
275
295
250
280
315
345
370
165
195
220
240
265
215
245
280
310
340
290
320
345
370
395
370
405
440
470
500
110
130
150
170
190
125
145
165
190
210
160
185
205
230
250
205
230
260
285
310
Speed Switch Positions
3
4
1
1950
2170
1635
1770
1970
1480
1600
1780
1290
3
4
1
1790
1990
1120
1630
1810
1020
1470
1635
900
0.7
0.8
0
0.1
425
455
275
305
545
585
350
395
645
675
575
605
815
850
730
770
285
305
325
355
315
340
390
425
400
425
545
585
505
535
775
815
345
370
200
225
445
475
255
290
530
550
425
455
670
700
540
575
235
260
225
255
270
290
295
325
320
350
435
465
400
430
590
625
290
310
150
175
370
395
195
220
420
445
315
340
535
565
400
430
215
230
165
190
230
255
200
230
270
295
305
335
335
360
425
460
Second Stage COOL" Speed − cfm
2
3
1750
1965
1605
1805
1400
1605
First Stage COOL" Speed − cfm
2
3
1195
1380
1095
1225
970
1105
Second Stage
0.2
0.3
0.4
0.5
0.6
345
380
415
445
475
440
485
530
570
605
640
670
700
730
765
805
845
885
925
965 1005 1015
390
425
460
490
520
465
500
540
570
600
630
670
715
755
790
860
900
945
975 1010 1040 1060
260
290
325
355
385
330
375
415
455
490
490
520
555
580
610
620
660
700
735
770
290
325
360
390
425
360
395
430
465
495
505
540
575
605
635
665
705
745
790
830
200
225
250
275
305
255
285
315
355
390
370
395
425
450
475
465
500
535
570
600
220
245
275
305
330
260
295
325
355
385
370
405
440
470
505
495
530
570
595
625
G61MPV / Page 29
1
4
2195
2015
1800
1
4
1560
1385
1245
0.7
0.8
505
535
645
685
795
800
550
580
630
660
830
865
415
445
530
570
635
665
805
840
455
485
525
560
665
700
875
905
330
355
425
455
500
525
630
665
360
390
415
445
540
570
655
690

Advertisement

loading