Lennox G61MPV Engineering Data page 32

Dave lennox signature collection multi−position − two−stage heat − variable speed blower gas furnaces
Hide thumbs Also See for G61MPV:

Advertisement

BLOWER DATA
G61MPV−60D−135 BLOWER PERFORMANCE (less filter)
Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side.
0 through 0.80 in. w.g. External Static Pressure Range
ADJUST"
ADJUST"
Switch
S
tc
P
Positions
iti
+
1
NORM
ADJUST"
Switch
Switch
Positions
+
1
NORM
1
Factory default jumper setting.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm.
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 470 cfm.
G61MPV−60D−135 BLOWER MOTOR WATTS
Jumper Speed
J
S
d
Positions
Positions
0
0.1
+" (Plus) SETTING ( Adjust" Jumper at +" Setting)
HEAT"
Tap 1 155
185
Speed
S
d
Tap 2 215
250
Tap 3 315
350
Tap 4 435
465
COOL"
Tap 1 95
120
Speed
S
d
Tap 2 115
135
Tap 3 145
175
Tap 4 205
240
NORM" (Normal) SETTING ( Adjust" Jumper at NORM" Setting)
HEAT"
Tap 1 130
155
Speed
Speed
Tap 2 165
195
Tap 3 240
270
Tap 4 335
365
COOL"
Tap 1 80
95
Speed
Speed
Tap 2 90
115
Tap 3 130
150
Tap 4 150
180
−" (Minus) SETTING ( Adjust" Jumper at −" Setting)
HEAT"
Tap 1 100
120
Speed
Speed
Tap 2 130
155
Tap 3 170
200
Tap 4 225
260
COOL"
Tap 1 65
80
Speed
Speed
Tap 2 70
90
Tap 3 95
120
Tap 4 135
155
G61MPV / Page 32
Second Stage HEAT" Speed − cfm
1
1
2
1505
1705
1365
1550
1225
1380
First Stage HEAT" Speed − cfm
1
1
2
1385
1570
1250
1425
1135
1265
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
0.2
0.3
0.4
0.5
0.6
220
255
285
315
340
285
325
360
390
425
390
430
460
490
530
500
530
575
615
655
145
170
190
215
240
160
185
210
235
260
215
250
275
300
330
280
320
350
380
410
180
205
235
260
285
230
265
300
330
360
310
345
380
415
440
405
440
480
515
550
115
135
160
190
210
140
165
190
215
230
170
195
225
255
275
220
255
285
315
345
140
165
190
215
240
180
210
235
265
285
235
270
300
330
360
300
335
375
410
435
100
120
140
160
180
110
130
155
175
200
145
170
190
215
235
175
200
220
245
270
Speed Switch Positions
Second Stage COOL" Speed − cfm
3
4
1
1900
2110
1615
1740
1920
1455
1545
1720
1305
3
4
1
1760
1930
1135
1595
1775
1025
1430
1585
915
0.7
0.8
0
0.1
365
390
215
225
455
490
275
315
565
605
405
440
695
735
530
575
265
290
250
285
290
315
290
330
355
385
425
465
445
480
615
655
305
330
155
180
385
415
215
250
470
500
305
340
585
620
405
445
230
255
185
215
250
265
230
260
300
320
315
355
375
405
445
485
265
290
125
150
310
330
155
185
390
420
220
250
465
490
295
325
195
215
145
170
220
240
160
190
250
270
245
280
300
325
325
365
2
3
1730
1945
1580
1780
1400
1600
First Stage COOL" Speed − cfm
2
3
1205
1365
1105
1235
985
1115
Second Stage
0.2
0.3
0.4
0.5
0.6
265
305
335
365
400
360
400
440
475
505
475
515
550
585
630
620
670
725
780
825
320
360
390
420
450
375
420
455
490
525
505
550
590
635
670
700
745
800
855
900
210
245
270
300
330
295
335
360
385
420
380
420
455
490
520
485
530
570
610
650
245
280
310
335
370
295
335
370
405
435
400
445
480
515
555
530
580
625
670
705
175
200
225
245
270
215
250
280
305
335
280
315
350
390
425
360
395
435
470
505
195
225
250
280
305
225
255
285
315
345
315
355
385
415
445
405
445
485
520
550
1
4
2190
1985
1780
1
4
1540
1390
1235
0.7
0.8
435
465
540
575
670
715
870
915
485
515
565
605
710
750
940
980
355
385
455
490
545
575
690
735
400
430
470
500
590
625
740
775
295
320
365
395
460
490
545
580
330
355
380
415
480
515
580
610