BLOWER DATA
G61MPV−60C−091 BLOWER PERFORMANCE (less filter)
Bottom Return Air, Return Air from Both Sides or Return Air from Bottom and One Side.
0 through 1.00 in. w.g. External Static Pressure Range
ADJUST"
ADJUST"
Switch
S
tc
Positions
P
iti
+
1
NORM
ADJUST"
Switch
Switch
Positions
+
1
NORM
1
Factory default jumper setting.
N/A − First and second stage HEAT positions shown cannot be used on this model.
NOTES − The effect of static pressure is included in air volumes shown.
First stage HEAT is approximately 91% of the same second stage HEAT speed position.
First stage COOL (two−stage air conditioning units only) is approximately 70% of the same second stage COOL speed position.
Continuous Fan Only speed is approximately 38% of the same second stage COOL speed position − minimum 500 cfm.
Lennox Harmony IIIt Zone Control Applications − Minimum blower speed is 458 cfm.
G61MPV−60C−091 BLOWER MOTOR WATTS
J
S
d
Jumper Speed
Positions
Positions
0
0.1
+" (Plus) SETTING ( Adjust" Jumper at +" Setting)
HEAT"
Tap 1 255
280
Speed Tap 2 325
S
d
360
Tap 3 495
525
Tap 4 625
660
COOL"
Tap 1 180
200
S
Speed Tap 2 200
d
225
Tap 3 245
270
Tap 4 355
380
NORM" (Normal) SETTING ( Adjust" Jumper at NORM" Setting)
HEAT"
Tap 1 185
210
Speed
Speed
Tap 2 240
270
Tap 3 385
410
Tap 4 480
510
COOL"
Tap 1 110
130
Speed
Speed
Tap 2 140
160
Tap 3 185
210
Tap 4 245
275
−" (Minus) SETTING ( Adjust" Jumper at −" Setting)
HEAT"
Tap 1 145
165
Speed
Speed
Tap 2 175
200
Tap 3 275
305
Tap 4 340
370
COOL"
Tap 1
90
105
Speed
Speed
Tap 2 105
125
Tap 3 145
165
Tap 4 190
215
Second Stage HEAT" Speed − cfm
1
1
2
1560
1770
1400
1575
1245
1400
First Stage HEAT" Speed − cfm
1
1
2
1420
1625
1280
1465
1145
1290
Motor Watts @ Various External Static Pressures − in. wg.
First Stage
0.2
0.3
0.4
0.5
0.6
305
330
355
390
420
390
425
460
500
540
555
590
620
650
680
700
740
780
815
855
225
250
280
300
320
250
280
305
330
350
300
335
365
390
420
405
435
465
495
520
235
265
290
315
340
305
340
375
410
445
435
455
480
510
540
540
570
600
605
670
155
180
205
230
250
185
205
230
250
265
235
265
290
320
350
305
335
365
395
420
190
210
235
255
280
225
255
280
305
335
330
360
385
410
435
405
440
475
505
535
125
145
165
185
205
150
170
195
215
235
190
215
235
260
280
240
265
290
315
345
Speed Switch Positions
3
4
1
1895
2110
1665
1745
1930
1515
1565
1745
1340
3
4
1
1780
1965
1240
1615
1790
1060
1445
1610
940
0.7
0.8
0
0.1
450
475
305
340
580
615
395
440
710
710
615
645
890
890
800
840
345
370
390
420
375
395
485
520
445
470
655
700
550
585
930
960
365
390
230
260
475
505
300
335
656
595
465
495
705
740
585
626
275
295
285
315
285
310
345
380
380
395
485
525
450
480
680
720
300
320
175
195
360
385
220
250
460
485
365
390
570
600
460
490
225
245
215
240
255
270
255
285
305
325
385
410
370
395
485
520
Second Stage COOL" Speed − cfm
2
3
1790
1990
1625
1815
1445
1645
First Stage COOL" Speed − cfm
2
3
1245
1410
1125
1270
1015
1145
Second Stage
0.2
0.3
0.4
0.5
0.6
375
415
450
475
505
490
540
585
620
655
675
705
740
755
775
880
920
960
985 1005 1030 1000
455
485
520
550
585
555
590
625
655
680
740
785
830
860
890
990 1020 1050 1060 1070 1045 1005
290
320
350
375
405
370
410
450
485
520
530
565
595
625
650
670
710
750
785
820
350
380
415
440
465
420
460
495
525
550
565
610
650
680
715
765
810
855
885
910
225
250
275
295
320
280
315
350
375
400
410
435
460
485
510
520
550
580
610
640
270
300
325
350
375
315
345
380
405
430
440
470
495
535
570
555
590
625
660
700
G61MPV / Page 23
1
4
2175
2020
1800
1
4
1585
1430
1270
0.7
0.8
530
560
690
730
790
765
615
640
710
735
925
930
430
460
560
595
680
690
855
870
490
525
580
615
745
775
940
960
340
365
430
460
535
555
675
700
395
425
455
495
605
630
735
765

Advertisement

loading